Specifications – Rice Lake 880 Performance Series Panel Mount Indicator/Controller - Relay Card Option Installation Manual User Manual
Page 4
J1
J2
J3
Connector J1
Pin
Signal
1
K1
Common
2
K1
Normally Open
3
K2
Common
4
K2
Normally Open
5
K3 Common
6
K3
Normally Open
7
K4
Common
8
K4
Normally Open
Table 1. Relay Card
Pin Assignments
Figure 2. Relay Card Installation
15. Connect to the relay card as shown in Table 1.
16. Reassembly control box to the DIN rail.
17. Reconnect all connectors to the back of the controller assembly.
18. Reconnect power to the indicator.
Note
The indicator automatically recognizes all installed option cards when the unit is powered on. No
hardware-specific configuration is required to identify the newly-installed card to the system. However, Slot 1
must be configured for the desired output in the batch menu. See the Technical/Service Manual (PN 158387).
Specifications
4 SPST
Normally Open Dry Contact Relays
250 VAC @ 3A
30 VDC @ 3A
Relay Protection
The use of external fusing to limit current is recommended. Relay COM-NO are transient
protected to 400V @ 600W
Relay Contacts
Displayed as Slot 1, Bit 1-4 in the setpoint configuration menu.