J1

J2

J3

Connector J1

Pin

Signal

1

K1

Common

2

K1

Normally Open

3

K2

Common

4

K2

Normally Open

5

K3 Common

6

K3

Normally Open

7

K4

Common

8

K4

Normally Open

Table 1. Relay Card

Pin Assignments

Figure 2. Relay Card Installation

15. Connect to the relay card as shown in Table 1.

16. Reassembly control box to the DIN rail.

17. Reconnect all connectors to the back of the controller assembly.

18. Reconnect power to the indicator.

Note

The indicator automatically recognizes all installed option cards when the unit is powered on. No
hardware-specific configuration is required to identify the newly-installed card to the system. However, Slot 1
must be configured for the desired output in the batch menu. See the Technical/Service Manual (PN 158387).

Specifications

4 SPST

Normally Open Dry Contact Relays
250 VAC @ 3A
30 VDC @ 3A

Relay Protection

The use of external fusing to limit current is recommended. Relay COM-NO are transient

protected to 400V @ 600W

Relay Contacts

Displayed as Slot 1, Bit 1-4 in the setpoint configuration menu.

230 W. Coleman St. t Rice Lake, WI 54868 t USA

U.S. 800-472-6703 t Canada/Mexico 800-321-6703 t International 715-234-9171 t Europe +31 (0) 88 2349171

www.ricelake.com www.ricelake.mx www.ricelake.eu www.ricelake.co.in m.ricelake.com

© Rice Lake Weighing Systems

11/2013

PN 153859