Digital I/O Expansion Card Installation Instructions

6. Ensure no excess cable is left inside the

enclosure and tighten cord grips.

7. Reconnect power to the indicator.
8. Use the DIG I/O menu to configure digital I/O

as necessary. See the

920i

Installation Manual

(PN 67887),

820i

Installation Manual (PN

93018), or

720i

Installation Manual (PN

103121) for more information.

The indicator automatically recognizes all installed

option cards when the unit is powered on. No

hardware-specific configuration is required to identify

the newly-installed card to the system.
For the

920i

, a digital I/O expansion card installed at

connector J5 on the CPU board is configured as slot 1;

a card installed at connector J6 is configured as slot 2.

A digital I/O card installed in the

720i

or

820i

is

configured as slot 2.

Specifications

I/O Channels

Up to 24, 5V/TTL, each software
configurable as input or output

Relay Supply Voltage

5 VDC, 1A maximum

Input Voltage

0–5.5V maximum

Digital Outputs

24mA balanced outputs with
sink/source capability

Input Protection

8-screw terminal: 300W transient
voltage suppression for ESD, EFT
(electrical fast transients), tertiary
lightning, and system-generated
transients per IEC 60001-4-2,
60001-4-4, and 60001-4-5; European
Standards EN50082 and EN61000-4
Remaining I/O: 2KV HBM, 100V
machine model

I/O Connection

50-pin ribbon connector, 8-screw
terminal connector