Rice Lake 920i Dual Channel A/D Card User Manual

Page 2

Advertising
background image

2

920i

Dual Channel A/D Card Installation Instructions

8. If using 6-wire load cell cable (with sense

wires), remove jumpers JP1 and JP2 before

r e i n s t a l l i n g c o n n e c t o r J 1 . F o r 4 - w i r e

connections, leave jumpers JP1 and JP2 on.

Remove jumpers JP3 and JP4 for 6-wire

connections to J2.

9. When connections are complete, reinstall load

cell connectors on the A/D card and use cable

ties to secure the load cell cables to the inside

of the enclosure.

10. Position the backplate over the enclosure and

reinstall the backplate screws. Use the torque

pattern shown in Figure 3 to prevent distorting

the backplate gasket. Torque screws to 15 in-lb

(1.7 N-m).

1

3

5

14

17

16 12

9

8

7

10

11

18

15

4

2

6

13

Torque backplate screws

to 15 in-lb (1.7 N-m)

Figure 3. 920i Enclosure Backplate

11. Ensure no excess cable is left inside the

enclosure and tighten cord grips.

12. Reconnect power to the indicator.
13. The

920i

automatically recognizes all installed

option cards when the unit is powered on. No

hardware-specific configuration is required to

identify the newly-installed card to the system.
Calibrate the A/D card using the procedures

described in the

920i

Installation Manual, PN

67887.

Specifications

Excitation Voltage

10 ± 0.5 VDC,
16 x 350¾ or 32 x 700

 load

cells per A/D card

Sense Amplifier

Differential amplifier with
4- and 6-wire sensing

Analog Signal Input Range

–10 mV/V to +70 mV/V

Analog Signal Sensitivity

0.3 uV/grad minimum @ 7.5 Hz
1.0 uV/grad typical @ 120 Hz
4.0 uV/grad typical @ 960 Hz

A/D Sample Rate

7.5–960 Hz, software selectable

Input Impedance

>35 M¾ typical

Internal Resolution

8 000 000 counts

Wt Display Resolution

9,999,999

Input Sensitivity

10 nV per internal count

System Linearity

±0.01% of full scale

Zero Stability

±150 nV/°C, maximum

Span Stability

± 3.5 ppm/°C, maximum

Input Voltage Differential

±800 mV referenced to earth
ground

Input Overload

Load cell signal lines ±10 V
continuous, ESD protected

RFI/EMI Protection

Signal, excitation, and sense
lines protected