December 2010

69092

920i

®

Programmable HMI Indicator/Controller

Single-Channel A/D Card Installation Instructions

PN 68532

Use the following procedure to install single-channel

A/D cards in

920i

indicators:

1. Disconnect indicator from power source.

W arning

Disconnect power before removing
indicator backplate.

2. Place indicator face-down on an antistatic

work mat. Remove screws that hold the

backplate to the enclosure body.

Use a wrist strap to ground yourself and
protect components from electrostatic
discharge (ESD) when working inside the
indicator enclosure.

3. Carefully align the large option card

connector with connector J5 or J6 on the CPU

board. Press down to seat the option card in

the CPU board connector.

4. Use the screws and lockwashers provided in

the option kit to secure the other end of the

option card to the threaded standoffs on the

CPU board (see Figure 1).

J5

J6

Figure 1. Installing Option Card Onto CPU Board

5. To attach cables from load cells or junction

boxes to the A/D card, route the cables

through the cord grips and wrap the shield

w i r e s a r o u n d t h e g r o u n d s tu d o n t h e

enclosure. Secure shield wires to the ground

stud with the kep nut included in the parts kit.
See the

920i

Installation Manual, PN 67887,

for more information about grounding cables.

6. Next, remove connector J1 from the A/D

card. The connector plugs into a header on the

card (see Figure 2). Wire the load cell cable

from the load cell or junction box to

connector J1 as shown in Table 1.
If using 6-wire load cell cable (with sense

wires), remove jumpers JP1 and JP2 before

reinstalling connector J1. For 4-wire

installation, leave jumpers JP1 and JP2 on.

4*( 

4*(o

4&/ 

4&/o

&9$ 

&9$o

+

+1

+1

Figure 2. Single-Channel A/D Card

Table 1. A/D Card Pin Assignments

J1

Connector Pin

Function

1

+SIG

2

–SIG

3

+SENSE

4

–SENSE

5

+EXC

6

–EXC

For 6-wire load cell connections, remove jumpers JP1 and
JP2.