Rice Lake 920i Six Card Expansion Board User Manual

Six-card expansion board installation instructions, 920i, Programmable hmi indicator/controller

Advertising
background image

January 2005

71285

920i

Programmable HMI Indicator/Controller

Six-Card Expansion Board Installation Instructions

PN 69783

This document contains procedures used to install
six-card expansion boards in wall mount models of

920i

indicators.

See the

920i

Installation Manual, PN 67887, for

general installation and configuration information,
including option card slot numbering and port
assignments.

NOTE:

The slot/location jumper on the six-card

expansion board must be set to the 3–8 position for all
standard installations. The 9–14 jumper position is
used only in special applications using two six-card
expansion boards.

For applications using two six-card expansion boards,
use cable PN 87164 to connect the J2 connector on the
first board (slots 3–8) to J1 on the second board (slots
9–14).

Disconnect power before opening indicator
enclosure.

Use a wrist strap to ground yourself and
protect components from electrostatic
discharge (ESD) when working with circuit
boards.

Option cards are not hot-pluggable. Disconnect power to the
expansion board before installing option cards.

Ensure that option cards are aligned with standoffs and
installed on the correct connector. Installing cards on the
adjacent connector (for example, plugging a card intended for
J6 onto the J3 connector) may damage the card.

Figure 1. Six-Card Expansion Board

J3

J4

J5

J7

J6

J9

J1

J10

1

J8

+6V

–6V

ISP

1

J2

1

1

1

+3.3V

+5V

GND

+6V

–6V

POWER IN

POWER OUT

U3

SLOT/LOCATION JUMPER

9–14

3–8

9–14

3–8

GND
GND

–6V

+6V

GND
GND

Advertising