5 recording the cal factor – Rice Lake Combination System - Precision Loads PL9700 Indicator User Manual

Page 12

Advertising
background image

8

PL9700 Installation Manual

4.5

Recording the Cal Factor

The cal factor is a number related to the calibration of
each channel of the indicator. Should you need to
c h a n g e i n d i c a t o r s , u s i n g t h e c a l f a c t o r w i l l
considerably speed the process. By entering into the
new indicator the cal factors from the old indicator,
the new indicator will have the same calibration. Use
the space below to record your indicator’s cal factor.

Truck (channel 1) cal factor ______________

Trailer (channel 2) cal factor ______________

1. Press and hold the

Menu

key about 5 seconds

until the information display shows Setup
menu.

2. After releasing the

Menu

key, the information

display will show Setup selection and the
weight display will show Setup.

3. To find the cal factor for the truck (channel 1)

channel, press the

Up

or

Down

key until the

information display shows Calibrate Channel
1
.

4. Press the

CAL

softkey.

The information display will show Set Ch. 1
Cal-Factor
.

5. The last number of the weight display will be

flashing, telling you that number is ready to
be changed. If you are only recording the
number and not changing it, record it above
and then press the

Enter

softkey.

6. If you are installing a replacement indicator

and want to enter the truck (channel 1)
channel cal factor from the previous indicator,
press the

left arrow

or

right arrow

softkey to

select the number for changing.

7. When the number on the weight display

matches your truck (channel 1) cal factor,
press the

Enter

softkey to store the cal factor

in the indicator’s memory.

The information display will show Store Ch. 1
Cal-Factor
and then return to Setup selection
and the weight display will show Setup.

8. To find the cal factor for the trailer (channel

2) channel, press the

Up

or

Down

key until the

information display shows Calibrate Channel
2
.

9. Press the

CAL

softkey.

The information display will show Set Ch. 2
Cal-Factor.

10. The last number of the weight display will be

flashing, telling you that number is ready to
be changed. If you are only recording the
number and not changing it, record it on the
previous page and then press the

E n t e r

softkey.

11. If you are installing a replacement indicator

and want to enter the trailer (channel 2)
channel cal factor from the previous indicator
press the

left arrow

or

right arrow

softkey to

select the number for changing.

12. To change the value of the number, press the

Up

or

Down

key.

13. When the number on the weight display

matches your trailer (channel 2) cal factor,
press the

Enter

softkey to store the cal factor

in the indicator’s memory.

14. After recording or resetting the cal factor

numbers, press the

Cancel

softkey.

The information display will briefly show
CANCEL - Setup and then return to normal
operation.

Advertising