The 8 ft lead to the indicator has four conductors. The Black and Red conductors may be wired to the GND and
+12Vdc terminals as shown on the rear terminal strip of the PL9710. The Green conductor connects to terminal L1
(Limit 1) and the White conductor connects to terminal L2 (Limit 2) on the rear strip of the PL9710. The 15 ft Red
(Power) lead of the PL9774 is wired to the positive power source of the lights or alarms being used, with
light/alarm ground wired to the negative power source terminal. Green (L1) and White (L2) conductors are wired
to the positive terminals of the light or alarm as shown in Figure 2.

Figure 2. Digital Output Drawing

Program Setup

To set limits and limit deadband,

1. Press the

Menu

key for 5 seconds to enter the

Setup

mode.

2. Advance to

Set Limit 1

by pressing the

Up Arrow

key on the upper right area of the PL9710.

3. Enter the value desired for Limit 1.

4. After entering the screen will ask you to enter a Limit 1 deadband.

The factory default setting is +/- 500 for the deadband.

5. Change the deadband if desired, otherwise press

Cancel

and forward to

Set Limit 2

.

6. Enter the value desired for Limit 2, followed by either change to or

Cancel

of the desired deadband for

Limit 2.

7. Exit the

Setup

mode.

Operation

Verify Limit 1 and Limit 2 setpoint operation. If using lights, Limit 1 will activate once the setpoint threshold is
reached. Limit 1 will deactivate when Limit 2 is reached. Either flashing or continuous lights or LED’s may be
used.

Specifications

Relay Rating:

250 Vac/Vdc, 5 amp

Module Size:

3"W x 7"L x 2"H (76 mm x 178 mm x 51 mm) NOTE: For in-cab mounting only.

Deadband:

A relay trips when the display is equal to or greater than the limit. The relay will be untripped if the display
drops to a value that is less than the limit minus that deadband value.

NOTE: Module is for in-cab mounting only. Module not to be installed externally unless housed inside a weatherproof enclosure.