0 installation, 1 leveling, 2 grounding – Rice Lake BenchMark CW-80 Base User Manual

Page 6: 3 load cell wiring and specifications, Installation

Advertising
background image

2

Benchmark HD Series

2.0

Installation

Remove the scale from the shipping container and place it in the desired location. Select a location for the CW-80B

that is reasonably level and free of unnecessary vibrations and air currents.

2.1

Leveling

CAUTION

Do not lift the scale by the spider assembly that supports the platter. Lifting by the spider can damage the
load cell. Always lift under the base when moving the scale.

Remove the scale platter and locate the bubble level. Adjust the four corner feet on the base until the bubble level

on the inside frame of the unit reads level. When level, the base should not rock and all four feet should have solid

contact with the support surface. If using a column with the scale, adjust the two column feet until they make solid

contact with the support surface.

2.2

Grounding

Bench scales can build up a charge of static electricity during weighing operations. If powerful enough, this charge

can travel through the load cell cable to the indicator. To prevent this, all bench scales should be grounded so that

static charges and transient electrical surges can drain directly to ground.
A chassis ground screw is located on the bottom of the platform (number 26 on the parts diagrams shown on pages

4 and 5) to facilitate grounding. Use a ground wire of at least 18 gauge copper to connect this screw to the same

earth ground as the attached indicator.

2.3

Load Cell Wiring and Specifications

Use the wiring code shown in Table1-1 when connecting the CW-80B bench scale to your indicator. Refer to the

indicator manual for information about indicator connections and calibration.

Table 2-1. RL1380 load cell wiring code

Color

Function

Green

+Excitation

Black

–Excitation

White

+Signal

Red

–Signal

Yellow

Shield

Table 2-2. Load cell specifications

RL1380 Load cell specifications

Full scale output

2.0 mv/V

Bridge resistance

350

Material

Stainless steel

Temperature

14°F–104°F / -10°C to 40°C

(compensated range)

Safe overload

150% full scale

Rated excitation

10V AC/DC (15V maximum)

Combined error

0.03% full scale

Insulation resistance

1000 M

Seal type

Environmentally protected

Cable length

10 ft/3.1 m

Advertising