Configuring the cw-90/90x, Pc or server configuration, Cw-90/90x – Rice Lake WeighVault for CW-90/CW-90X - Installation Instructions User Manual

Page 3

Advertising
background image

MODE

VALSET

ID

DATA

000000

RANGE

TARGWT

TARG%

CHKWGH

REGION

UID

CONSC#

KEYED

PUSH

SCALE

FEATUR

SERIAL

DIGI/O

PFORMT

VERS

OFF

ON

LIGHTS

SOLID

GRAPH

NEGCKW

OFF

ON

AUTO

BOTH

RDONLY

XXXXXXX

XXXXXXX

ID

ACCUM

EXIT

T&D

TEST

SETUP

AUDIT

CALIBR

BRIGHT

CONFIG

Only displayed if

turned on

from Setup menu

Only displayed if

turned on

from Setup menu

OFF

PORT1

PORT2

PORT3

OFF

TYPE

PORT

OFF

VAULT

BUFFER

. . .

PORT1

PORT 2

PORT 3

TRIGGE

Same as PORT 1

DEMAND

TARGET

WAITSS

STREAM

L-STAB

OFF

Same as PORT 1

TRIGGE default

is set to OFF

COMAND

. . .

3

Configuring the CW-90/90X

1. From the SETUP menu, navigate to CONFIG » FEATUR » CHKWGH.
2. Set DATA » TYPE to VAULT.
3. Set DATA » PORT to PORT 2 for use with the Internal WLAN option, or PORT 3 for the wired Ethernet

option. If using your own External converter, select the port you wired the converter to (PORT 1 or PORT

2).

4. Under the SERIAL menu, the TRIGGE parameter for the port selected must be set to something other than

OFF. Choose a parameter based on when the data should be sent to WeighVault.

5. If using multiple

CW-90/90X

units on the same network, set UID (Unit ID) to a desired identification

number. This number will be referenced in WeighVault to identify the unit.

6. Turn the CHKWGH » ID parameter to ON.

Figure 5. CW-90/90X menu

PC or Server configuration

Indicators communicate with the host PC through TCP

Port #9090. In order for this communication to take

place, the indicator's Ethernet or WLAN option card

needs to know the IP address of the host PC. Therefore,

the host will need a static (not dynamic) IP address.
If using a network server, ask yo ur ne two rk

administrator for the IP address of the server, and

confirm the address is static. If using a PC, refer to the

instructions supplied with the PC, or Windows, to help

you set up the computer with a static IP address.
If your PC or network is running a firewall, it may be

necessary to create an exception for TCP Port 9090.

Configuration Internal Ethernet or WLAN Option Cards

The Ethernet or WLAN option card will require

specific configuration to work properly with

WeighVault. Both option cards can be configured using

a network-based Windows application called Device

Installer, which is provided on the WeighVault DVD

and the CD included with the option card. However,

with the WLAN option card, an initial configuration is

required via RS-232 before Device Installer can be

used.

Note

Configuration of the Ethernet or WLAN option
card should be performed by someone familiar
with general computer networking, and more

specifically, familiar with the network the card is going to attach
to. At minimum, you must know the IP address and subnet of
the host PC, and if connecting via WLAN, the network SSID
and security settings (pass keys and phrases).

More detailed configuration instructions are available on the CD
and in the manuals provided with the option cards.