1 safety, 2 operating requirements, 1 safety 1.2 operating requirements – Rice Lake DeckHand/DeckHand Rough-n-Ready System User Manual

Page 6

Advertising
background image

2

DeckHand Portable Floor Scale

1.1 Safety

Safety Symbol Definitions

Indicates an imminently hazardous situation that, if not avoided, will result in death or serious
injury.

Indicates a potentially hazardous situation that, if not avoided could result in serious injury or
death, and includes hazards that are exposed when guards are removed.

Indicates a potentially hazardous situation that, if not avoided may result in minor or moderate
injury.

Indicates information about procedures that, if not observed, could result in damage to
equipment or corruption to and loss of data.

General Safety

Do not operate or work on this equipment unless you have read and understand the
instructions and warnings in this manual. Contact any Rice Lake Weighing Systems dealer
for replacement manuals. Proper care is your responsibility.

Before attempting to operate this unit, make sure every individual who operates or works with this unit has
read and understands the following safety information.
Failure to heed may result in serious injury of death.
DO NOT allow minors (children) or inexperienced persons to operate this unit.
DO NOT operate without all shields and guards in place.
DO NOT jump on the scale.
DO NOT use for purposes other then weight taking.
DO NOT place fingers into slots or possible pinch points.
DO NOT use any load bearing component that is worn beyond 5% of the original dimension.
DO NOT use this product if any of the components are cracked.
DO NOT exceed the rated load limit of the unit.
DO NOT make alterations or modifications to the unit.
DO NOT remove or obscure warning labels.

DO NOT use near water.

Before opening the unit, ensure the power cord is disconnected from the outlet.

Keep hands, feet and loose clothing away from moving parts.

1.2

Operating Requirements

Electrical Grounding

Rolling or wheeling loads onto the scale can build up large static charges that may damage the attached indicator
unless it is properly grounded to prevent ESD. This is especially true in dry environments where charges drain off
slowly, or if wheeling on materials which already contain a static charge, like rolls of paper or plastic film material
that have been recently spooled.

To prevent ESD damage, the indicator requires a three-prong 120 VAC outlet plug with continuous earth
ground. Do not attempt to use the scale with two-prong 120 VAC power without a ground.

DANGER

WARNING

CAUTION

Important

WARNING

Important

Load Cell Excitation

Rated Excitation: 10 VDC

Maximum Excitation: 15 VDC

mV/V Signal Output: 2 mV/V

Grade Level Requirements

The bubble level built into the platform should indicate
a level condition in use. On uneven floors, place
temporary shims under feet not contacting the floor.

Safe Static Overloading Capacity

Maximum: 150% of scale capacity

Advertising