PN 52948

Use the following procedure to install the panel mount
option:

NOTE:

The IQ plus 355 panel mount bezel gasket

meets NEMA 12 requirements for dust-proof
installations.

1. Use the cutout template to make

a 9.8" W x 6.3" H (249 mm W x
160 mm H) cutout in the panel.
Ensure cutout is far enough
f r o m p a n e l e d g e t o
accommodate bezel: panel mount
bezel dimensions are 10.5" W x
7.0" H (267 mm W x 178 mm H).

2. If attached, remove the tilt stand

from the indicator enclosure.

3. Peel adhesive backing from the

bezel gaskets, then press bezel
into the panel cutout.

4. Insert the indicator into the panel

mount bezel from the rear. Align
h o l e s i n s i d e o f i n d i c a t o r
enclosure with holes in the bezel
flange.

5. Use the 1/4-20 x 1/2" cap screws

and lock washers provided to
attach the L-brackets to the
outside of the installed bezel and
indicator.

6. Start the four 1/4-20NC x 1 3/4"

round-head machine screws into
the panel mount brackets. Place a
few drops of a removable-strength thread adhesive (such as Loctite

®

) on the screw threads to prevent

loosening in high-vibration environments. Tighten screws until the indicator is held securely against the
panel. Figure 2 shows a top view of a completed panel mount installation.

Figure 2. Panel Mounted IQ plus 355 (Top View)

See the

IQ plus 355 Installation Manual

, PN 51980, for more information about installation procedures and

requirements.

Indicator

L-Brackets (2)

1

/

4

-20NC x

1

/

2

cap screws

with lockwashers (2)

1

/

4

-20NC x 1

3

/

4

machine screws (4)

Bezel

P A N E L

Installed Bezel

Panel

L-Bracket

Bezel and gasket assembly

Indicator

Figure 1. IQ plus 355 Panel Mount Kit Components