Counting operations, Counting mode key functions – Rice Lake Farm Bars - 390DC User Manual

Page 3

Advertising
background image

IQ plus 390-DC Operator Card

3

Counting Operations

The illustration below shows the IQ plus 390-DC keypad and piece count mode key functions.

NOTE:

Legal-for-trade applications require product to be sold by weight rather than an equivalent parts

count. Operator access to piece count mode is disabled when the indicator is shipped from the factory. To
use piece count mode, access must be enabled when the indicator is configured.

Piece count mode is entered by pressing the

MODE

(

GROSS/NET

) key from normal weighing mode. In

count display mode, the display shows the number of
parts rather than weight, the arrow annunciator at the
right side of the LCD display points to piece count
(PC), and pressing the

PRINT

key sends the CFMT

print format data string to the serial port.

IQ plus 390-DC counting operations are summarized
below:

Acquire Parts Sample

1. Place empty parts container on scale. Wait for

the standstill annunciator (

), then press

TARE

to acquire the tare weight of the

container.

2. Press

MODE

to enter piece count mode.

3. Press the

SAMPLE

(

UNITS

) key to enter

sample acquisition mode.

4. The indicator display shows the message

Addnnn

, where

nnn

is the sample quantity to

be placed on the scale. Add the number of
parts shown or choose a different sample size
by pressing the

SAMPLE

key to scroll through

the selectable sample quantities (5, 10, 20, 50,
100).

5. Once the sample quantity is on the scale,

press

ENTER

to calibrate the indicator for

counting the new parts. The indicator display
shows the message

–CNT–

as it acquires the

sample weight, then switches to count display
mode and shows the part quantity.

If the weight of the sample quantity is insufficient
for piece counting, the indicator automatically
requests the next higher sample quantity by
showing the

Addnnn

message again. If the sample

quantity is at maximum (100) and the sample
weight is still not sufficient, the indicator shows
the message

CNTERR

.

Display Part Weight

To view gross and net weight of parts, press

MODE

to switch from count display mode to

normal weighing mode.

Print Ticket

1. Wait for the standstill annunciator (

).

2. Press the

PRINT

key to send piece count data

to the serial port.

T

ZERO

GROSS

NET

TARE

UNITS

PRINT

T

B/G

Units

POWER

ENTER

SAMPLE

MODE

PRINT

I / O

New sample /

change sample quantity

Send data to

serial port

(CFMT format)

Not used

Switch between gross, net,

and piece count mode

Acquire tare /

acquire sample

COUNTING MODE KEY FUNCTIONS

Advertising
This manual is related to the following products: