2

IQ plus 390-DC Live Weighing Option

Serial Data Considerations

W h e n o p e r a t i n g i n l ive w e i g h i n g m o d e w i t h
AUTOPRT set OFF, ensure that the acquired weight
display time (DSPTIM parameter) is set to a large
enough value to allow the operator time to press the

PRINT

key to generate a demand print ticket, if

required. In live weighing mode, the

PRINT

key can

send data to the serial port only while the acquired
weight is displayed; pressing the

PRINT

key at any

other time acquires a new weight sample.

Demand print data (SERIAL menu STREAM
parameter set OFF) uses the NFMT ticket format if a
tare is in the system, GFMT if no tare is acquired or
entered. The <G> format command on the GFMT
ticket and the <N> format command on the NFMT
ticket both represent the animal weight.

When streaming continuous data (SERIAL menu
STREAM parameter set to LFT or INDUST), the
weight data displayed or printed depends on the value
set for the WEIMOD parameter: If WEIMOD is set to
BLANK and no weight data is shown on the current
display, streamed weight data is also blank.

Live Weighing Program Menu

Figure 1. ANIMAL Submenu on IQ plus 390-DC PROGRM Menu

XXXXXXX

XXXXXXX

VERS

PROGRM

PFORMT

SERIAL

CALIBR

CONFIG

FORMAT

ANIMAL

ACCESS

ENABLE

DSABLE

000040

000001–

002400

SMPTIM

000080

000001–

999999

DSPTIM

OFF

ON

WEIMOD

NORMAL

BLANK

AUTPRT

GO

DELAY

PWRUPM

• • •

(same as standard
PROGRM menu)

sample and display times

specified in 0.1-second intervals

PROGRM Menu / ANIMAL Submenu

Parameter

Choices

Description

Level 3 Submenus

ACCESS

ENABLE

DSABLE

Animal mode access. Specify ENABLE to use the live weighing option; specify DSABLE to
operate as standard indicator.

SMPTIM

000040

number

Sample time. Specifies, in 0.1-second intervals, the sample time during which animal
weight is acquired. The default value (000040) is 4 seconds.

DSPTIM

000080

number

Display time. Specifies, in 0.1-second intervals, how long the acquired animal weight is
displayed. The default value (000080) is 8 seconds.

AUTPRT

OFF

ON

Automatic print. Specifies whether animal weight data is automatically sent to the serial
port once the weight is acquired.

WEIMOD

NORMAL

BLANK

Weigh mode. Specifies whether the indicator display shows the current scale weight
(NORMAL) or is blank (no weight data) when the acquired weight display time expires.

Table 1. ANIMAL Submenu Parameters on PROGRM Menu