Counting Operations

The illustration below shows the IQ plus 590-DC keypad and piece count mode key functions.

NOTE:

Legal-for-trade applications require product to be sold by weight rather than an equivalent parts

count. Operator access to piece count mode is disabled when the indicator is shipped from the factory. To
use piece count mode, access must be enabled when the indicator is configured.

Piece count mode is entered by pressing the

MODE

(

GROSS/NET

) key from normal weighing mode. In

count display mode, the display shows the number of
parts rather than weight, the arrow annunciator at the
right side of the LCD display points to piece count
(PC), and pressing the

PRINT

key sends the CFMT

print format data string to the serial port.

IQ plus 590-DC counting operations are summarized
below:

Acquire Parts Sample

1. Place empty parts container on scale. Wait for

the standstill annunciator (

), then press

TARE

to acquire the tare weight of the

container.

2. Press

MODE

to enter piece count mode.

3. Press the

SAMPLE

(

UNITS

) key to enter

sample acquisition mode.

4. The indicator display shows the message

Addnnn

, where

nnn

is the sample quantity to

be placed on the scale. You can do one of the
following:

Add the number of parts shown.

Choose a different sample size. Press the

S A M P L E

key t o s c r o l l t h r o u g h t h e

selectable sample quantities (5, 10, 20,

50, 100) or use the numeric keypad to
specify a custom sample size.

Specify a known piece weight. Press the

S A M P L E

key t o s c r o l l t h r o u g h t h e

selectable sample quantities until the

PC

WGT

prompt is shown. Use the numeric

keypad to enter the piece weight.

5. Once the sample quantity is on the scale,

press

ENTER

to calibrate the indicator for

counting the new parts. If a sample size was
specified, the indicator display shows the
message

–CNT–

as it acquires the sample

weight, then switches to count display mode
and shows the part quantity. If a known piece
weight was specified, the display switches to
count display mode immediately.

Display Part Weight

To view gross and net weight of parts, press

MODE

to switch from count display mode to

normal weighing mode. To view the current piece
weight while in count mode, press the

DISPLAY

TARE

key.

Print Ticket

1. Wait for the standstill annunciator (

).

2. Press the

PRINT

key to send piece count data

to the serial port.

T

4

9

0

8

5

2

7

6

3

CLEAR

DISPLAY

TARE

ZERO

GROSS

NET

TARE

UNITS

PRINT

B/N

Units

POWER

ENTER

SAMPLE

MODE

PRINT

I / O

New sample / change

sample quantity

Send data to

serial port

(CFMT format)

Not used

Switch between

gross, net, and

piece count mode

Acquire tare /

acquire sample

COUNTING MODE KEY FUNCTIONS

Display current

piece weight

Power on/off

T