Rice Lake iQUBE2 12 VDC Remote Power Supply User Manual

12 vdc remote power supply, Installation instructions, J1 j2

Advertising
background image

May 2009

110564

iQUBE

2

Digital Diagnostic Junction Box

12 VDC Remote Power Supply

Installation Instructions

PN 108434

This document contains procedures for installing the 12 VDC remote power supply, PN 108434. This power
supply is recommended for use in

iQUBE

2

installations that do not have AC power available at the scale

platform.
See the

iQUBE

2

Installation Manual, PN 106113, for general installation and configuration information. The

“Power Considerations” section of that manual includes a discussion of how to calculate current draw and

voltage drop for a given system.

Disconnect power before opening power
supply enclosure.

Use a wrist strap to ground yourself and
protect components from electrostatic
discharge (ESD) when working with circuit
boards.

This power supply provides 44 watts of power, with continuous current of 3.7 amps, to power a full system over

typical distances from scalehouse to scale. The power supply is mounted in an 8 x 6 x 4-inch NEMA 4X FRP
enclosure and includes a transient protection board, PN 109396. The transient board option for the

iQUBE

2

, PN

110949, includes the transient protection board and a mounting bracket for the

iQUBE

2

enclosure.

Figure 1 shows the transient protection board connectors. Wire the output DC power cable from the V+ and V–
terminals to the corresponding transient protection board terminals in the

iQUBE

2

enclosure.

Figure 1. Transient Protection Board Connections

The transient boards will handle the maximum current provided by the power supply, but large current loads

increase the voltage drop across the inductive chokes and could reduce the input voltage to the

iQUBE

2

system

below the 6 VDC minimum.

NOTE:

When using 4-wire power cable, the cable voltage drop between the remote power supply and the

iQUBE

2

can be

cut in half by using two wires for both the supply and return cable runs. Cabling can be doubled by wiring to both

V+ terminals and both V– terminals on the transient board connectors.