6. Navigate to the CONFIG menu and press the

Connect

softkey (see Figure 3).

12/20/2010

01:57PM

Connect

CONFIG

COMM SEL

UPDATE

iQube2 Configuration

Default

Save

and Exit

Upload

Download

IQUBE2

PORT4

SERIAL

PROGIN

DISPLAY

PORTTYPE

PORTTYPE

Figure 3. CONFIG menu

7. The serial number will show (i.e., 123XX456

*NONE* *NONE* NONE*)

If the serial number does not show, check

wiring and dip switches.

Add a Secondary Board to the System

1. Under CONFIG, navigate to the BOARDS

parameter and select the

Auto Assign

softkey.

12/20/2010

01:57PM

CONFIG

COMM SEL

UPDATE

iQube Boards

Number of iQube2 boards on port

Save

and Exit

Auto Assign

Manual

Assign

IQUBE2

PORT4

SERIAL

PROGIN

DISPLAY

PORTTYPE

PORTTYPE

BOARDS

CELLS

COMM

SCALES

DIGIO

Figure 4. BOARDS parameter

2. Green lights on the

iQUBE

2

CPU boards will

start blinking on all cells.

3. Press and release the SETUP button (S1) on

secondary board #1.

This makes cells 5-8 available to the system

and registers its serial number with the primary

board. The lights on the board will stop

blinking.

4. Once the secondary unit has been assigned,

press the SETUP button (S1) on the primary

board.

5. You will see a screen showing the primary

board serial number and any assigned

secondary board serial numbers.

12/20/2010

01:57PM

Auto Assign

Edit

Primary
0

123XX456

Secondary

1)

65

456XX789

2)

__

_________

3)

__

_________

Done

Figure 5. Primary and Secondary Boards screen

6. Press the

Done

softkey.

Configure and Add Load Cells

1. Under CELLS, set the capacity and m/v.
2. Add cells 5-8 to Scale 1 under the SCALES »

SERIAL menu.

12/20/2010

01:57PM

Remove

SCALES

AVAILABLE Cells

ASSOCIATED Cells

SCALES

CELL#1

CELL#2
CELL#3
CELL#4
CELL#5
CELL#6

Scale 1

Scale 2
Scale 3
Scale 4
Scale 5

CELLS

SMPRAT

A1 A3 B1 B3

A2 A4 B2 B4

Figure 6. Cells 5-8 added to Scale 1

3. Download to the

iQUBE

2

.

Add iQUBE

2

to the 920i

1. From the SCALES menu, drop down to

CONFIG.

2. Press the

Change Type

softkey until Available

iQubes is displayed.

12/20/2010

01:57PM

Connect

Default

Save

and Exit

Upload

Download

CONFIG

SCALES

AVAILABLE IQUBES

ASSOCIATED IQUBES

SCALES

Port 4 - Scale 1

Scale 1

Scale 2
Scale 3
Scale 4
Scale 5

Figure 7. Scale Association screen

3. Select Port 4 - Scale 1 and press the

ADD

softkey to add it to Associated iQUBES.

4. Press the

Save and Exit

softkey.

5. Continue with calibration using Section 4.0 of

the installation manual.