0 introduction, Jb1010 – Rice Lake JB1010 Signal/Excitation Trim User Manual

Page 4

Advertising
background image

1

The JB1010 is a summing junction box and trimming device for up to ten strain gauge load cells. In new ap-
plications that use a single junction box, the JB1010 can be custom con fi g ured to fi t many unique ap pli ca tions.
It allows either signal or excitation trimming of three load cell arrangements: individual load cells, pairs of load
cells in sec tions, or a combination of individual/and paired load cells. It allows use of an odd number of load
cells without modifi cation.

As a re place ment board for existing applications in the fi eld—even as part of a multiple junction box trim ming
network—the JB1010 can re place many boards. It is ide al as a single replacement product for many sep a rate
boards for truck scales, tank scales, and track scales. This product can be used in multiple con fi g u ra tions. Most
of these confi gurations are used to match existing systems using multiple junc tion boxes.

When the JB1010 is used as a re place ment for existing junction boxes, the confi guration characteristics of the
other trim ming devices must be matched for proper operation. Help for de ter min ing the characteristics of exist-
ing devices will be found in Section 8.0, Using the JB1010 in an Existing System.

Standard JB1010 units have a local tran sient sup pres sion net work that provides zone pro tec tion against most
light ning induced tran sients, par tic u lar ly when used with cell wiring in metal conduit.

In addition to the NEMA 4 FRP junction box, the JB1010 is also available as a board-only product.

1.0 Introduction

Figure 1-1. JB1010 Board

SHD

–SIG

+SIG

–EXC

+EXC

+EXC

–EXC

+SIG

–SIG

SHD

CELL A

CELL

B

SHD

–SIG

+SIG

–EXC

+EXC

+EXC

–EXC

+SIG

-SIG

SHD

SHD

–SIG

+SIG

–EXC

+EXC

+EXC

–EXC

+SIG

–SIG

SHD

CELL A

CELL B

SHD

–SIG

+SIG

–EXC

+EXC

+EXC

–EXC

+SIG

–SIG

SHD

CELL A

CELL B

SHD

-SIG

+SIG

–EXC

+EXC

+EXC

-EXC

+SIG

–SIG

SHD

CELL A

CELL B

+EX

+SE

–EX

–SE

+SI

–SI

SHD

CELL

1A

CELL

3A

CELL/SECT
4B

CELL

5A

CELL/SECT
6B

CELL

7A

CELL/SECT
8B

CELL

9A

CELL/SECT
10B

SECT5

+EXC

SECT5

–EXC

SECT4

+EXC

SECT4

–EXC

SECT3

+EXC

SECT3

–EXC

SECT2

+EXC

SECT2

–EXC

SECT1

+EXC

SECT1

–EXC

TO INDICATOR

SECTION 1

SECTION 2

SECTION 3

SECTION 4

SECTION 5

JB1010

CELL/SECT
2B

CELL A

CELL

B

100K

Ω

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

TRANSIENT PROTECTION

SW1B

SW1A

SW2B

SW2A

SW3B

SW3A

SW4B

SW4A

SW5B

SW5A

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

100K

Ω

Advertising