1 safety, 2 operating requirements, 1 safety 1.2 operating requirements – Rice Lake RoughDeck AX User Manual

Page 6

Advertising
background image

30

RoughDeck HE AutoLift

1.1 Safety

Safety Symbol Definitions

Important

CAUTION

WARNING

DANGER

Indicates an imminently hazardous situation that, if not avoided, will result in death or serious
injury.

Indicates a potentially hazardous situation that, if not avoided could result in serious injury or
death, and includes hazards that are exposed when guards are removed.

Indicates a potentially hazardous situation that, if not avoided may result in minor or moderate
injury.

Indicates information about procedures that, if not observed, could result in damage to
equipment or corruption to and loss of data.

General Safety

WARNING

Do not operate or work on this equipment unless you have read and understand the
instructions and warnings in this manual. Failure to follow the instructions or heed the
warnings could result in injury or death. Contact any Rice Lake Weighing Systems dealer for
replacement manuals. Proper care is your responsibility.

Failure to heed may result in serious injury of death.

DO NOT allow minors (children) or inexperienced persons to operate this unit.
DO NOT operate without all shields and guards in place.
DO NOT jump on the scale.
DO NOT use for purposes other then weight taking.
DO NOT place fingers into slots or possible pinch points.
DO NOT use any load bearing component that is worn beyond 5% of the original dimension.
DO NOT use this product if any of the components are cracked.
DO NOT exceed the rated load limit of the unit.
DO NOT make alterations or modifications to the unit.
DO NOT remove or obscure warning labels.

DO NOT use near water.

Before opening the unit, ensure the power cord is disconnected from the outlet.

Keep hands, feet and loose clothing away from moving parts.

1.2

Operating Requirements

The following are basic operating requirements for the RoughDeck floor scale.

Electrical Grounding

For systems where the scale is connected to a 115 VAC circuit, the indicator must be directly connected to an earth

ground with a ground interface cable of no more than 3Ω resistance throughout its length.

Load Cell Excitation

Rated Excitation: 10 VDC
Maximum Excitation: 15 VDC

Grade Level Requirements

The supporting surface for the four feet of the scale must be level within

1

/

4

inch of horizontal.

End Load Capacity

133% full scale at 30,000 lbs