3 operating requirements – Rice Lake RoughDeck FXB Flexure Lever Floor Scale User Manual

Page 7

Advertising
background image

Introduction and System Setup

3

1.3

Operating Requirements

The following is a list of operating requirements necessary to operate the RoughDeck FXB flexure base scale.

Electrical Grounding

For systems where the scale is connected to a 120 VAC circuit, the instrument must be directly connected to an

earth ground with a ground cable that has no more than three ohm resistance throughout its length and connections.

Grade Level Requirements

The supporting surface for the four feet of the scale must be level to within 1/4" of horizontal.

Load Cell Excitation

Rated Excitation - 10 VDC
Maximum Excitation - 15 V

Safe Static Overloading Capacity

Maximum - 150% of the scale capacity

Temperature

Compensated range 0 to 150

°

F (-18 to 65

°

C).

Advertising