3 operating requirements – Rice Lake RoughDeck FXB Flexure Lever Floor Scale User Manual
Page 7
Advertising
Introduction and System Setup
3
1.3
Operating Requirements
The following is a list of operating requirements necessary to operate the RoughDeck FXB flexure base scale.
Electrical Grounding
For systems where the scale is connected to a 120 VAC circuit, the instrument must be directly connected to an
earth ground with a ground cable that has no more than three ohm resistance throughout its length and connections.
Grade Level Requirements
The supporting surface for the four feet of the scale must be level to within 1/4" of horizontal.
Load Cell Excitation
Rated Excitation - 10 VDC
Maximum Excitation - 15 V
Safe Static Overloading Capacity
Maximum - 150% of the scale capacity
Temperature
Compensated range 0 to 150
°
F (-18 to 65
°
C).