Translink limited warranty, Maintenance and replacement parts, Replacing a load cell – Rice Lake Translink™ Parallel Link Truck Scale Assembly User Manual

Page 9: Replacement parts, 1 replacing a load cell, 2 replacement parts

Advertising
background image

9

6. Maintenance and Replacement Parts

6.1

Replacing a Load Cell

1.

Jack up the girder chair and weighbridge away from the pin in the load cell
assembly. Jack it high enough only to remove the pin.

2.

Remove the pin from the links and pull it through the hold on the stand. Remove
the links from the load cell, and remove the load cell.

3.

Position the new load cell on the bearing pad. Attach the two links to each end
of the load cell. Slide the pin in through the hold of the stand. Position the links
on each end of the pin.

4.

Lower the girder chair and weighbridge Gently onto the pin so the load cell is
not damaged by excessive shock.

5.

Check if the load cell mounts are level (see Section 2.33 Re-leveling, Securing,
and Grouting the Base, on page 4).

6.

Test the scale, and recalibrate if necessary.

6.2

Replacement Parts

Tension Pin

Base Plate

Leveling Bolt

Pin

Bearing Pad

Link

Girder Chair

Load Cell

Description Qty A* B* C*

Translink

TM

Mount (excluding load cell).....................17970.........17971 ......... 17972

Tension Pin..................................................2..........15302........15300 ......... 15300
Base Plate...................................................1 ........ 18458.........18455 ........ 18458
Leveling Screw.............................................4.........H702-1........H702-1......H702-1
Pin...............................................................1.........18470.........18468 ......... 18469
Bearing Pad.................................................1.........18452.........18453 ......... 18453
Link, Weldless End.......................................2.........17809.........17810 ......... 17809
Girder Chair.................................................1..........18465.........18467 ........ 18466
Double-Ended Shear Beam Load Cell .........1..........(see Load Cell Product Selection

Guide for load cell part numbers).

*A – mount compatible with load cells RL75223/5223 in capacities of 50,000,

65,000 and 100,000 lb each.

*B – mount compatible with load cells RL75040A/65040A in capacities of

25,000 and 40,000 lb each.

*C – mount capatible with load cells RL75040A/65040A in capacities of 50,000,

60,000 and 75,000 lb each.

Advertising