DIGITAL NETWORK BRIDGE

DNB100

F7

RING COMMUNICATIONS INC.

J2 - 9 pin (DB9) RS232 signals :

A null-modem (LapLink) cable can be used to connect two DNB100's together if the DNB100's are
close enough to each other. Two modems for leased line operation can be used to increase the
distance between two bridges.

If you are going to make your own cable the following is a description of the pinouts of the DB9
connector on the DNB100. The RS232 cable should not exceed 50 feet in length.

J2

SIGNAL

DIRECTION/

PIN#

NAME

DESIGNATION

1

DCD

Data Carrier Detect, input.

2

RXD

Receive Data, input.

3

TXD

Transmit Data, output.

4

DTR

Data Terminal Ready, output.

5

GND

Signal Ground.

6

DSR

Not used.

7

RTS

Request to Send, output.

8

CTS

Clear to Send, input.

9

RI

Not connection.