Multi stage – Ring Communications RM5000EX User Manual

Page 38

Advertising
background image

RM5000EX Operations Manual March 2011

Multi stage:

SW2 1 and 2 on PCB500 (EX500) is used for selecting number of digits in call numbers when the
system is defaulted.:
1

2

OFF

OFF

Reserved

OFF

ON

2 Digit Dialing (10-55)

ON

OFF

3 Digit Dialing (100-155)

ON

ON

4 Digit Dialing (1000-1055)

1.

Set SW3 1 and 2 to OFF

2.

Set SW2 1 and 2 to number of call digits to 2,3 or 4

3.

Set SW2 4–8 for stage number (1-9)

4.

Push and release the Reset Switch on EX500 (SW4).

5.

Turn on SW3 1

6.

Set SW2 (EX500) to proper network address

7.

Push and release the Reset Switch on EX500 (SW4).

LED M (EX500) will blink 4 times during RAM Test .
The system is now operational.

DEFAULT CALL NUMBERS

SW2 4 5 6 7 8

STAGE

PORT

SW2 1 2

SW2 1 2

SW2 1 2

o 1

1 o

1 1

1 o o o o

1

00-37

38-3D

10-65
81-86

100-155
181-186

1100-1155
1181-1186

o 1 o o o

2

00-37

38-3D

10-65
81-86

200-255
281-286

1200-1255
1281-1286

1 1 o o o

3

00-37

38-3D

10-65
81-86

300-855
381-886

1300-1355
1381-1386

o o 1 o o

4

00-37

38-3D

10-65
81-86

400-455
481-486

1400-1455
1481-1486

1 o 1 o o

5

00-37

38-3D

10-65
81-86

500-555
581-586

1500-1555
1581-1586

o 1 1 o o

6

00-37

38-3D

10-65
81-86

600-655
681-686

1600-1655
1681-1686

1 1 1 o o

7

00-37

38-3D

10-65
81-86

700-755
781-786

1700-1755
1781-1786

o o o 1 o

8

00-37

38-3D

10-65
81-86

800-855
881-886

1800-1855
1881-1886

1 o o 1 o

9

00-37

38-3D

10-65
81-86

900-955
981-986

1900-1955
1981-1986

Gray area not recommended

Page38