USER'S GUIDE

Data Line & Signal Protection

Data Line & Signal Protection

Model A

Model C

www.smartpowersystems.com 1-800-882-8285

PN16000650 Rev.04-12

The new SmartNet II is the only

data line and signal protector

with easy installation

3

Features

• Easy installation with connection to ground

• Stand-alone data line and signal protection

• Protects any electronic equipment against surges that

come through the telephone and data line.

• Noticeably increases download speed (up to 200%)

• All units come with the necessary patch cables, except

on the coaxial and BNC models.

• No tools necessary for installation of Model A

• Available in colors black and computer gray

For T1, T3, 10/100/1000 Based-T, ISDN, DSL, etc.

• Handle data line with speed of over 300MHz

SmartNet II

2

Smart Power Systems Inc. is an engineering and
manufacturer of power quality products. The new
SmartNet II is the only data line and signal protector
with easy installation for telephone equipment/DSL
(RJ11), network (RJ45), big screen tv/cable (coaxial)
and CCTV/security system (BNC).

FOR SAFETY AND OPTIMUM PERFORMANCE,
THE SMARTNET SHOULD BE PROPERLY
GROUNDED.

THE USE OF THE SMARTNET IN LIFE SU-
PPORT APPLICATIONS WHERE FAILURE OF
THE SMARTNET IS EXPECTED TO CAUSE THE
FAILURE OF THE LIFE SUPPORT EQUIPMENT
IS NOT RECOMMENDED.

Specifications and Applications

4

Specifications and Applications

5

Specifications and Applications

6

Model A
Size (HxWxD) (In) : 1.37" x 1.31" x 3.31"
Weight: 0.11 Lb.

Model B
Size (HxWxD) (In) : 2.0" x 1.31" x 3.06"
Weight: 0.11 Lb.

Model C
Size (HxWxD) (In) : 2.12" x 1.31" x 3.06"
Weight: 0.16 lb.

7

Installation

The SmartNet protects your equipment from surges that come
through the data and signal line. To ensure that your equipment
is completely protected, use a TBF™ power filter or UPS-TBF
from Smart Power Systems.

1) SmartNet must be installed as close as possible to the
equipment to be protected.
2. Turn off all equipment.
3 Unplug the RJ11/45, Coaxial or BNC cable from the equip-
ment you want to protect and plug into the "IN" jack on the
SmartNet II. Plug the other end to the network jack or cable
wall jack.
4. Plug the provided network cable (RJ11 or RJ45 only) to the
"OUT" jack on the SmartNet II. Plug the other end of the pro-
vided network cable into the equipment you want to protect.
5. Connect the SmartNet unit to ground. See instructions on
pages 8-11.

RJ45

SN-Net5e

MODEL

IN/OUT JACK

CLAMPING VOLTAGE

AND PIN CONNECTION

7.5 Volts protecting
pins 1 through 8 for
Network

SN-NPOE

RJ45

SN-Tel

RJ11

75 Volts protecting pins
1 through 8 for
POE Network

300 Volts protecting
pins 4 and 5 for
phone line

APPLICATION

10/100/1000Based-T
Cat5e. For protection
of high speed
networked equipment

For protection of POE
(Power Over Ethernet)
network, T-1 equipment

For protection of
phone systems, fax,
answering machines
and DSL/modems

RJ11

300 Volts protecting
pins 4 and 5 also 3
and 6 for dual phone
line

SN-Tel2

MODEL

IN/OUT JACK

CLAMPING VOLTAGE

AND PIN CONNECTION

SN-TV

Coaxial

75 Volts for protecting
against surges between
center and shield

75 Volts for p
against surges between
center and shield

rotecting

SN-BNC

BNC

For protection of phone,
answering machines
and fax with 2 phone
lines

APPLICATION

For protection of TV
systems, cable box
and DVR

For protection of
security systems,
CCTV and camera

Advertising