background image

Page 24 - MS5500 Installation Manual

DRIVER DOOR

ACTUATOR

Yellow/white wire
(-) AUX. 1 output

CUT

PASSENGER DOOR
ACTUATORS

FACTORY DOOR LOCK MODULE

White/blue wire
(-) UNLOCK

White/green wire
(-) LOCK

(-) Door Lock wire

(-) Door Unlock wire

15A FUSE

CONNECT
TO +12V

LOCK/UNLOCK
SWITCH

DRIVER DOOR

ACTUATOR

Yellow/white wire
(-) AUX. 1 output

CUT

PASSENGER DOOR
ACTUATORS

FACTORY DOOR LOCK MODULE

White/green wire
(+) UNLOCK

White/blue wire
(+) LOCK

(+) Door Lock wire

(+) Door Unlock wire

15A FUSE

CONNECT
TO +12V

LOCK/UNLOCK
SWITCH

DRIVER DOOR

ACTUATOR

Yellow/white wire
(-) AUX. 1 output

CUT

PASSENGER DOOR
ACTUATORS

White/blue wire
(-) UNLOCK

CUT

CONNECT
TO +12V

15A FUSE

LOCK/UNLOCK
SWITCH

CUT

White/green wire
(-) LOCK

Driver Door Priority
Wiring Diagrams

Positive Trigger System

For positive trigger door locking
systems, wire as shown at left.

Negative Trigger System

For negative trigger door locking
systems, wire as shown at right.

For a description of Driver’s Door Priority
Mode, see Remote Transmitters -
Transmitter Operating Modes.

Voltage Reversal System

-or-

Aftermarket Actuators

For voltage reversal door locking
systems, wire as shown at right.