Bussmann, Power module, Switch ps – Cooper Bussmann Power Module PS User Manual

Page 2: All-in-one module

Advertising
background image

Bussmann

®

Power Module

Switch PS

All-In-One Module

Form No. PS

Page 2 of 5

BIF Doc# 1145

Standard Shunt Trip Ratings

Amp

Max

Max

1

Momentary

Rating

Voltage

Inrush

Ontime

Inrush

30-100

200

120V, 60HZ

4 amps

1.5 cycles

140VA

400

Bussmann

®

Power Module™ Switch – Dimensions and Lug Data

Catalog

NEMA 1

NEMA Depth

Number

Amp

Dimensions

1

Depth

3R, 12

2

3R,12

Lug Size

3

PS3

30

20∑H ≈ 16∑W 8fiΩ•∑

20∑H ≈ 20∑W

8∑

#14 - #8 Al or Cu

PS6

60

20∑H ≈ 16∑W 8fiΩ•∑

20∑H ≈ 20∑W

8∑

#14 - #2 Al or Cu

PS1

100

20∑H ≈ 16∑W 8fiΩ•∑

20∑H ≈ 20∑W

8∑

#8 - 1/0 Al or Cu

PS2

200

30∑H ≈ 20∑W 8fiΩ•∑

30∑H ≈ 24∑W

8∑

#6 - 250 kcmil Al or Cu

PS4

400

55∑H ≈ 40∑W 13∑

(2) 3/0 - 500 kcmil Al or Cu

1

Standard over size enclosure to mount control power transformer fire safety interface relay and control terminal blocks.

2

Contact factory for dimensions for NEMA 4 enclosure.

3

Optional neutral lug size same as line and load.

Maximum Horsepower Rating of Switch – Sizing Based on Motor Type

Amp Rating of Switch

30A

60A

100A

200A

400A

PS3

PS6

PS1

PS2

PS4

Voltage

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

208AC-3P

5

5

3

10

10

10

20

15

15

40

40

30

75

75

60

240AC-3P

5

5

5

10

10

10

20

20

15

50

40

30

125

75

75

480AC-3P

10

10

10

30

25

20

50

40

30

100

75

75

250

150

150

600AC-3P

15

15

10

30

30

25

60

50

40

125

100

100

250

200

200

Column Sizing Guidelines:

A Maximum horsepower rating of switch with Class J fuses, light-duty inrush
B Maximum horsepower rating of switch with Class J fuses, medium-duty inrush
C Maximum horsepower rating of switch with Class J fuses, heavy-duty or typical elevator cross line start

The above table can be used for estimating switch size for motor loads based upon the motor horsepower. Size the switch so that
the Class J, time-delay fuses are used at a minimum of 150% of motor full load amps or next size up (for light starting duty
applications, Column A). For general applications, excluding wound rotor and DC motors, NEC

®

430-52 allows sizing at 175%

of motor full load amps or the next standard size per NEC 240-6 (Column B). If sizing at 175% will not allow the motor to start,
NEC 430-52 will allow the fuses to be sized up to 225% of motor full load amps or the next size down (Column C).

Note: In sizing the fuses, the motor FLA, is per Table 430-150, not per nameplate information.

Inrush currents of motors may vary, consult motor manufacturer data for correct sizing.
On elevator applications, motor load plus auxiliary loads need to be considered. Follow elevator manufacturer’s
recommendation for correct fuse sizing. For estimation purposes only, Column C can be used as a conservative
approximation.

Bussmann

®

8-29-01

XXXXXX

1

Will handle up to 447VA inrush.