Symtech SCA 1 With Line Laser User Manual

Page 6

Advertising
background image

Place a thick nylon bushing on the screw and insert
screw through the holes provided at the top of the
mast, place a thick nylon bushing on screw and self-
locking nut.

Tighten to a tension that allows for movement of
sighting unit, but provides sufficient friction to hold
unit in place when unattended.

NOTE: The mast has two sight unit mounting positions, mount in

the position that is most comfortable for the technician to
sight through

Sighting unit must be calibrated to the optical head prior
to alignment of headlamps.

Optical
Head

IN

Calibration

OUT of
Calibration

Adjustment

Thumb Screws

Optical
Head

2.5 SIGHTING UNIT CALIBRATION

Calibration of sighting unit must be performed prior to alignment of
headlamps.

Raise optical head of SCA 1

ISOColor to the approximate center of

mast.

Turn the sighting unit until you can see the front edge of the optical
head while looking through the sighting unit lens. Line on lens
should line up with the front edge of the optical head.

If line does not line up with the front edge of optical head, loosen
the thumbscrews on the lens and move the lens into alignment.
Tighten thumbscrews.

It is important that periodical checking of calibration of the sighting
unit be performed, to assure proper calibration.

NOTE: When technicians of differing heights are using the SCA 1

ISOColor and the sighting unit is relocated to the optional
mounting position for better viewing, the sight unit must be
checked for calibration and adjustment made accordingly.


2.6 FLOOR SLOPE LASER

The floor slope laser assembly is factory calibrated, DO
NOT
turn the level adjustment set screw.

The laser is used for floor slope measurement only. Remove
laser after floor slope measurements have been recorded.

On / Off

Knob

Level Adjuster
Set Screw

Fixture

Placement Pin

ON/OFF

Knob

Remove floor slope laser from packaging and insert front
fixture placement pin into hole on top and at front of the
rear area of the optical head, also there is an indentation
provided for the height adjustment screw to rest within.

Activate the laser by turning ON/OFF knob clockwise
(CAUTION: Excessive turning may damage laser
ON/OFF mechanism) to assure of functionality, turn off
laser. No further adjustment is required.

NOTE: Should calibration of the laser become necessary in

the future, Refer to “LASER CALIBRATION”.
Calibration, Section 5.1, Pg. 9.

Laser Battery Replacement

Unscrew back of laser and replace batteries with three (3), LR 44
button batteries or equivalent. Reverse process for assembly.

After battery replacement, CALIBRATION COULD BE REQUIRED.


5