Move glide plate up and down the mast through its full motion, by
depressing handle.

2.3 OPTICAL ALIGNMENT HEAD

Remove optical alignment head from shipping carton.
Inspect for any damage that may have occurred during
shipment i.e. lens, case, etc..

Attach optical alignment head to the mast glide plate by
aligning mounting holes of glide plate with the holes in
the optical head. Insert _ x 20 x _ allen head machine
screws through glide plate, place a _ x _ nylon spacers
on each upper screws, place a _ x

1

/

2

nylon spacers on

each lower screws, attach optical head and tighten
securely.

Remove protective paper covering from viewing window
on top of optical head.

Move optical head through the full range of movement to
assure of smooth operation.

2.4 VEHICLE ALIGNMENT MIRROR

Vehicle alignment mirror assembly is

enclosed

in the accessories box.

NOTE: Mount mirror assembly so that unit is

located directly over the optical head.

Insert 2, _ x 20 x 1

1

/

2

screws (Small Parts

Package) into mirror calibration block and attach all
to top of mast.

DO NOT TIGHTEN. Tighten to a tension that
allows for sufficient movement during calibration.
After calibration has been performed tighten
securely.

NOTE: Sighting unit must be calibrated to the optical head prior

to alignment of headlamps.

2.5 SIGHTING UNIT CALIBRATION

Calibration of sighting unit must be performed prior to alignment of
headlamps.

Raise optical head of CVA 3

EZ

to the approximate center of travel

of mast.

Turn the sighting unit until you can see the reflection of the front
edge of the optical head. Line on mirror should line up with the
front edge of the optical head.

If line does not line up with the front edge of optical head, rotate
mirror assembly until line is parallel with front of optical head.
Tighten screws.

It is important that periodical checking of calibration of the vehicle
alignment mirror be performed, to assure customer satisfaction.

2.6 FLOOR SLOPE LASER

The floor slope laser assembly is factory calibrated, DO
NOT
turn the level adjustment set screw which is at the
back of laser assembly.

The laser is used for floor slope measurement only. Remove
laser after floor slope measurements have been recorded

Glide

Plate

_ x _ Black

Nylon Spacers

Optical

Head

IN

Calibration

OUT of
Calibration

Optical
Head

On / Off

Knob

Level Adjuster
Set Screw

Fixture

Placement Pin

_ x 20 x _

Allen head

Optical

Head

_ x _ White
Nylon Spacers