Changeover of PRIMARY

(internal)

Coolant Tank to

ALTERNATE (external)

Coolant Tank

The VFX 1 can be used with multiple coolant types by simply switching between the PRIMARY (internal) Fluid Tank
and an ALTERNATE (external) Fluid Tank. The VFX 1 comes with one additional ALTERNATE (external) Fluid
Tank. Additional tanks can be purchased through Symtech Corporation or one of its Distributors. Inquire for a
Distributor location nearest you.



1)

Verify that all control panel valves are in neutral position, (Fig 1) and

flow control valves at hose ends are OFF.

2)

Connect to clean shop air (70-120psi).

3)

Move New ALTERNATE (external) coolant tank next to VFX 1.

Remove Lid from ALTERNATE (external) Tank container.

4)

Pull out the ALTERNATE (external) Tank connection hose from VFX

1 and connect coupler to ALTERNATE (external) Tank lid. Verify dip-
tube is open to atmosphere. (Fig 2)

5)

Turn Coolant Tank select valve to ALTERNATE (external) Coolant Tank.

6)

Turn AIR CONTROL valve (#1) and FLUID CONTROL valve (#3) to the

left, TOP OFF (

GREEN

). (Fig 3)

7)

Connect cone assembly to RED/NEW coolant flow control valve

at hose end.

8)

Place cone into fill spout of PRIMARY (internal)coolant fluid Tank,

SLOWLY open RED/NEW coolant flow control valve at hose end.

9)

Close RED/NEW coolant flow control valve at hose end when

all coolant has been purged from unit.

10)

Return all control panel valves to neutral position. (Fig 4)

11)

Replace lid on ALTERNATE (external) coolant tank. Connect

ALTERNATE (external) tank hose coupling.

12)

Turn AIR CONTROL valve (#1) and FLUID CONTROL valve (#3) to the left,

TOP OFF (

GREEN

). (Fig 5)

13)

Place cone assembly still connected to RED/NEW coolant flow control valve

into tool storage compartment at front of machine, or waist fluid container.
SLOWLY Open RED/NEW coolant flow control valve at hose end.

14)

Close RED/NEW coolant flow control valve at hose end when air has

been purged from line or a steady stream of coolant from ALTERNATE
(external) tank flows from unit.

15)

Return all control panel valves to neutral position. ( Fig 6)

16)

Unit is now ready to perform coolant system service with Exterior Tank

coolant.



Figure 3