Recommended wire and fuse size, Door panel, Testing vehicles gas supply piping – Thetford 9100 Series Installation Manual User Manual

Page 9

Advertising
background image

The distance the current travels from the battery to the refrigerator dictates the wire size. Undersized wire can

result in a voltage drop, which will affect the wattage output of the DC heater and result in reduced refrigerator
performance. Norcold recommends the installation of a fuse in the supply wiring between the battery and the
refrigerator. For optimum protection, install the fuse as close to the battery as possible.

Door Panels

Refrigerator doors allows insertion of decorative panels. Prepare panels to the following specifications:

Upper Door

Lower Door

Panel

Thickness

Models

Height

Width

Height

Width

962, 963

9162, 9163

14 17/32"

21 19/32"

31 5/8"

21 19/32"

3/16" max.

982, 983

9182, 9183

14 17/32"

21 19/32"

38 5/8"

21 19/32"

3/16" max.

Door Panel Insertion - Both Doors

Open door(s).

Grasp top of panel holder and pull away from the
door.

Slide decorative door panel into door frame slots.

To re-install door panel holder:

Align the bottom of panel holder with groove in door.

Rotate top of panel holder into the door groove.

Press along panel holder to insure that it is firmly seated.

Note: It may be necessary to seat the panel holder on the opposite side of the door.

Testing the Vehicle’s Gas Supply Piping

The propane gas supply piping must be inspected and tested for leaks from the refrigerator to main gas supply

tank. Use a leak detection solution. Do not test for leaks with an open flame.

If compressed air is used for leak testing, the gauge pressure must not exceed 1/2 pound per square inch (14

inches water column).

The appliance and its individual shut-off valve must be disconnected from gas supply system during any pressure testing

of that system at test pressures greater than 1/2 psig (14 inches water column).

The appliance must be isolated from gas supply system by closing its individual manual shut-off valve during any

pressure testing of that system at test pressures equal to or less than 1/2 psig (14 inches water column).

Check gas pressure to the refrigerator without other gas appliances operating. The pressure should not exceed

11 inches water column. With other appliances operating the pressure should not be less than 10.5" water column.

Figure 9

Panel Holder

Decorative Panel

Door Assembly

In

stal

li

ng

the Refrig

erator

Table 2
Recommended Wire and Fuse Size:

Models 962, 982, 9162, 9182

Models 963, 983, 9163, 9183

Min. Wire Size

Max. Fuse Size

Min. Wire Size

Max. Fuse Size

0’ - 20’

18 AWG

6 AMP

10 AWG

30 AMP

over 20’

18 AWG

6 AMP

8 AWG

40 AMP

WARNING

A circuit overload can result in an electrical fire when undersized wires or improperly sized

fuses are used. To prevent a possible electrical fire, follow ANSI A119.2 Standards, Norcold’s wire and
fuse specifications, or applicable state and local codes.

9

Advertising
This manual is related to the following products: