Install the lower and upper vents, Assemble the enclosure for the refrigerator, Key refrigerator dimensions – Thetford N1095 Series Installation Manual - 2/20/06 - 2/20/07 User Manual

Page 4

Advertising
background image

Installation Manual 4

Install the Lower and Upper Vents

1. Using the following chart, decide which vents and rough

opening (RO) sizes to use:

Certified Vent

P/N

RO Height

RO Width

Upper Roof

622293

N/A

N/A

Exhaust Cap

Upper Roof

616319

24 in.

5 1/4 in.

Exhaust Vent

Upper Exhaust

621156

13 3/4 in.

21 1/2 in.

& Lower Intake
Plastic

Lower Square

616010

9 3/4 in.

19 3/8 in.

Corner Intake

Assemble the Enclosure for the Refrigerator

1. Make sure the enclosure is 59.88 - 60.01 inches high x 23.50

- 23.63 inches wide x 24 inches deep.

2. Make sure the floor is solid and level.

- The floor must be metal or a wood panel and extend the full

width and depth of the enclosure.

- The floor must be able to support the weight of the refrigera-

tor and its contents.

3. Make sure there are no adjacent heat sources such as a

furnace vent, a hot water heater vent, etc.

Key Refrigerator Dimensions

These key refrigerator dimensions are for your reference as
necessary (See Art01735).

Refrigerator cabinet width w/o trim - 23.1 in. ...................... 1
Refrigerator width overall w/ trim - 24.8 in. ......................... 2
Refrigerator cabinet to side trim - 0.84 in. .......................... 3
Refrigerator cabinet height w/o trim - 62.0 in. ..................... 4
Refrigerator height overall w/ trim - 59.7 in. ........................ 5
Refrigerator cabinet to top/bottom trim - 1.13 in. ................ 6
Enclosure wall to hinges - 3.10 in. ..................................... 7
Refrigerator cabinet to center of handles - 40.5 .................. 8

2. Install the lower intake vent (See Art01602):

NOTE: The lower intake vent is also the service access

opening for the components on the rear of the refrig-
erator.

WARNING:

Make sure the bottom of the opening of the

lower intake vent is even with or immediately below the
floor level. This allows any leaking propane gas to
escape to the outside and not to collect at floor level.

- Make sure the bottom of the opening of the lower intake vent

[1] is even with or immediately below the floor level.

- Align the lower intake vent vertically below the coils [2] and

the condenser [3] of the refrigerator.

3. Install the upper exhaust vent:

CAUTION:

Make sure that no sawdust, insulation, or

other construction debris is on the refrigerator or in the
enclosure. Debris can cause a combustion hazard and
prevent the refrigerator from operating correctly.

NOTE: Tighten the screws of the upper roof exhaust cap to 10

inch-pounds max. Also make sure that the air flow
around the upper roof exhaust cap is not blocked or
decreased by other roof mounted features such as a
luggage carrier, an air conditioner, a solar panel, etc.

- If the design of the vehicle allows, install the roof exhaust

vent [4] directly above the condenser [3] of the refrigerator
(See Art01676):

- Install a baffle [5] to prevent stagnant hot air in the area

[6] above the refrigerator.

- Make sure there is less than 1/4 inch clearance [7]

between the baffle and the top of the refrigerator.

- Make sure the baffle is the full width of the inside of

the enclosure.

- If the design of the vehicle does not allow you to install the

roof exhaust vent directly above the condenser [3] of the
refrigerator (See Art01677):

- Align the roof exhaust vent [4] above the condenser [3]

of the refrigerator and move it inboard as necessary.

- Install two baffles [8] to prevent stagnant hot air in the

area [6] above the refrigerator.

- Make sure the baffles are the full width of the

inside of the enclosure.

- Make sure that the baffles are no more than 45°

from vertical [9].

Advertising