CAUTION

The use of an Extension cord is not recommended.

CAUTION

MAINTENANCE OF YOUR BATTERY IS IMPORTANT

1.

MAINTENANCE OF THE BATTERY IS IMPORTANT.
If the change of your battery is not properly sufficient, a decline in the cooling
performance of your refrigerator can be expected.

2.

NEVER USE A BATTERY CHARGER, A.C./D.C. CONVERTER, OR RECTIFIER
ETC. IN LIEU OF A BATTERY.
These electrical supplies generate high ripples or surge voltages which result is
inverter trouble.

3.

NEVER USE A COMMERCIAL INVERTER OR CONVERTER for operating your
refrigerator on A.C. since these devices do not hold the required constant frequency.

q

OPERATION

To start your refrigerator, set the thermostat control knob to “ON”.
Now your refrigerator has started operation.

q

PROTECTION SYSTEM

The D.C. power cord is made for negative (-) ground
system. Your refrigerator has an over current protection
system. Your refrigerator has an over current protection
system incorporated in the electronic circuit to prevent
damage to the inverter which may occur due to the reverse
connection.

If your refrigerator does not operate and the power lamp
does not light, the reverse connection problem, fuse
opened in the cigarette lighter plug body or other problem
exist in the inverter and the unit should be checked by an
authorized Norcold Service Center.

CAUTION

FOR MODEL MRFT-415, 440

Fuse is located in the cigarette lighter plug body of the D.C. cord (provided with
the refrigerator), and if the fuse blows, replace 8A glass fuse with new one.