Do not connect power supply until the fan is completely installed. Disconnect power to fan prior to service or maintenance.

1. This unit has rotating parts and may have sharp edges. Safety precautions should be exercised during installation, operation

and maintenance.

2. Do not use these fans in hazardous environments where the fan’s electrical system could provide ignition to combustible or

flammable materials.

3. Turn centrifugal impeller by hand to make sure it rotates freely. If the impeller does not rotate freely contact Tjernlund’s customer

service department at 800-255-4208.

4. If using the M-Series in a dryer application it must be periodically inspected. IMPORTANT: Disconnect power to fan prior to ser-

vice or maintenance. Remove dryer duct and remove any lint build-up from the impeller on both inlet and outlet sides of fan.

5. Ducted fans used for exhaust applications must always be vented to the outdoors.

6. CAUTION: “For General Ventilation Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors.”

7. Rated for air stream temperatures up to 140° F (60° C).

IMPORTANT: All wiring must be in accordance with the National Electrical Code. Verify supply voltage and power consumption of fan
are suitable for circuit fan will be added to.

GUARDS OR DUCTING ON INLET/OUTLET OF FAN MUST BE INSTALLED WHEN THE FAN IS WITHIN REACH OF PERSONNEL
OR WITHIN SEVEN (7) FEET OF WORKING LEVEL OR WHEN DEEMED ADVISABLE FOR SAFETY.

TJERNLUND PRODUCTS, INC.

1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com

READ OWNERS INSTRUCTIONS

CAREFULLY PRIOR TO

INSTALLATION. DO NOT DESTROY.

M-Series

Metal High Pressure In-Line Duct Booster® Fans

©2010 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED.

P/N: 8504147 REV B 0210

Models

M-4
M-6
M-8

TJERNLUND LIMITED 1 YEAR WARRANTY

Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a
period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to
repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address
listed below, postage prepaid. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND
PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PROD-
UCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY
ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIM-
ITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so that limitation may not apply to you. In addition, some states
do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclusion may not apply to you. This warranty gives
you specific legal rights and you may also have other rights which may vary from state to state. Send all inquiries regarding warranty work to Tjernlund
Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794. Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 • Email [email protected].

SPECIFICATIONS

Model

Volts

Watts

Amps

Free Air CFM (0” w.c.)

M-4

120

100

0.9

200

M-6

120

125

1.1

530

M-8

120

210

1.8

670