Tjernlund Santek Air Cleaners (Discontinued) 8504022 Rev 1 01/95 User Manual

Page 4

Advertising
background image

3.

Thorougly engage Access Door cam locks (Models XF, XC, XK) or Bottom Panel latches (Model SL-1200).
AN UNSECURED ACCESS OR BOTTOM PANEL WILL NOT ENGAGE THE INTERLOCK SAFETY
SWITCH AND UNIT WLL NOT OPERATE.

MOTOR MAINTENANCE

(Models XF & SL) Motors are permanently lubricated and need no oiling.

(Models XC & XK) MOTOR MUST BE OILED EVERY 6 MONTHS; TO OIL:

1. Turn Fan Speed Switch to "Off" and unplug power cord.

2. Open access door, remove collecting cell(s), pre-filter(s) and charcoal filter(s).

3. Oil tubes are located near top of motor. Use only 2 or 3 drops of SAE 20 non-detergent oil in each oil tube

hole. DO NOT OVERFILL.

S

S

TROUBLESHOOTING

Santek units are designed to give years of trouble-free operation. It is possible, however, that the unit may require
some minor service.

You may call your Santek dealer or call Santek for the location of the nearest dealer. This is definately recommended
if the unit blower does not work when the Fan Speed Switch is in the operating position and the unit is plugged in.

In some cases you may be able to detect the trouble and correct it yourself, fairly quickly. If the blower is working and
the unit makes continuous arcing "snapping" or "popping" noises, remove the collecting cell(s) and inspect them for
foreign material between the aluminum plates. Remove material carefully to avoid plate damage.

Observe the green LED light which will be "On" when Santek power supply (one-piece electrical system) is operating
properly. The LED will shut off briefly when the collecting cell arcs.

If the LED is not "On" when the blower is running, a problem with the collecting cell(s) or the power supply is indicat-
ed. Turn the fan speed switch "Off". Remove collecting cell(s). Close access doors and turn the fan speed switch to
"On".

If the LED is "On", inspect the collecting cell(s) for objects between the aluminum plates in the collecting section.
Also inspect the ceramic insulators on the ionizing section and repalce any that are broken or cracked.

If the LED fails to light when the air cleaner is running and the cell(s) have been removed, contact your dealer or
Tjernlund Products, Inc. at 1-800-255-4208.

WARRANTY

3

TJERNLUND LIMITED TWO YEAR WARRANTY

Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material
or workmanship for a period of (2) years from the date of original purchase or delivery to the original purchaser, whichever is earlier.
Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated war-
ranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE NO WARRANTIES
WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DIS-
CLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS
WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY
LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED WARRANTIES ARE LIMITED TO THE
STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so
that limitation may may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential
damages, so that above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also
have other rights which may vary from state to state. Send all inquires or products requiring warranty work to Tjernlund Products, Inc.
1601 9th Street, White Bear Lake, MN. 55110-6794 (651) 426-2993.

Advertising