Using GPIO and ReaderEnable

12

ThingMagic Vega Set Up Guide

Note:

Note that there is no GPO-1 connection. This signal is used for switching between

antennas 2 and 3.

Figure 1: Connector Cable

ReaderEnable

There are two connections that can be used to enable the reader. The Serial connector
provides access to the ReaderEnable1 signal. The GPIO connector provides access to
the ReaderEnable2 signal. At least one of these signals must be pulled to greater than
+2V for the reader to be active. These signals can be used to remotely turn the power off
for power savings. The ReaderEnable Jumper Terminator provided with your reader will
connect pins 4 and 5 of the GPIO connector providing +12VDC to the ReaderEnable2
input.