Processing Data from the Reader

Autonomous Configuration Tool v1.0 User Guide

25

Temperature Status Message

A

Temperature Status Message

will be returned approximately every 250ms (this will vary

based on the Region setting used as it depends on the internal frequency hopping
algorithm which is dependent on the region of operation).

When using

Read On GPI Trigger

mode the temperature status message is used as a

keep-alive when GPI is low (reading is turned off).

Table 6:

Temperature Status Packet Format

Message Example

A sample temperature status message indicating a temperature of 29C:

Field

Value

Description

Header (Hdr)

0xFF

Defines the start of the packet.

Data Length (Len)

0x0A

Defines the length, M, of the data field contained in the
packet. Length can be 0 – 248 bytes

OpCode

0x22

Autonomous reader message

Status Word

0x0000

Should not receive non-0x0000 status.

RFU

[9 bytes]

Reserved for future use. Data can be ignored

Temperature

[1 byte]

Internal temperature of the module in degrees Celcius.

Note:

If temperature exceeds 85C the module will begin
throttling reading and return 0x0504 status in

Read-

Cycle Reset/Keep-Alive

messages.

CRC-16
Checksum

[2 bytes]

See

CCITT CRC-16 Calculation

.

FF

0A

22

00

00

00031b028200820001

1D

B7

71

SOH

Length

OpCode

Status Word

RFU

Temperature

CRC