Immpul signal – Torbal BA Industrial Platform User Manual

Page 51

Advertising
background image

- 51 -

2. The scale will display options “Impuls” and” Signal”. To select Pulse Mode press the T key when

“Impuls” is displayed, to select Signal Mode press the T key when “Signal” is displayed.








23.3. Opto-isolator Output

The outputs are open collector optically isolated switches. Each output has a current rating of 100.ma and an
open circuit collector voltage rating of 24 VDC. If the outputs are used to drive relays each relay should have
a flyback diode, with at least a 100.ma rating, to protect the drive transistor. If relays are used as buffers to
the sorting equipment be sure the contacts have adequate ratings and are properly protected from inductive
loads.

IMMPUL

SIGNAL

Advertising