Torbal Industrial Bench Scales User Manual

Page 3

Advertising
background image

BA and BTA Models:

1. Press the MENU key
2. Wait for Port 1 (port 1) RS232 or Port 2 (port 2) USB to appear and press the T key.
3. Wait for Sending (Sending) to appear and press the T key.
4. Once a desired sending mode is displayed press the T key to activate.

o stab (o stb)

Button plus
Stability

Stable weighing result is transferred from the scale after pressing
the

key,

o (o )

Button Only

Weighing result is transferred from the scale after pressing the

key (no stability required)

Auto (auto)

Automatic

Weighing result is automatically transferred from the scale after it
stabilizes (no push key required)

Cont (Cont)

Continuously

Weighing results is continuously transferred from the scale at all
times. (no push key and no stability required)


Exchange data:

ƒ Transmit the weight (equivalent to the Print Key,

,

in weighing: Computer

→Scale: S I CR LF (53h 49h

0Dh 0Ah) – initiating signal, Scale

→Computer: scale

sends 16 Bytes of data as follows:

Byte

1

- The charater ‘-‘ or space

Byte 2

-

Space

Bytes

3,4 - digit or space

Bytes

5-9 - digit, comma, or space

Byte 10

-

Digit

Byte 11

-

Space

Byte

12

- k, l, c, p or space (for kg,lb,ct,pc, or%)

Byte

13

- g, b, t, c or %

Byte 14

-

Space

Byte 15

-

CR

Byte 16

-

LF

ƒ ‘Tare the weight’ (corresponds to the

→T← key in

weighing): Computer

→Scale: S T CR LF (53h 54h

0Dh 0Ah),
Scale

→Computer: no response.

ƒ ‘Zero the scale’ (corresponds to the key

→0← in

weighing): Computer

→Scale: S Z CR LF (53h 5Ah

0Dh 0Ah),
Scale

→Computer: no reponse.

ƒ ‘Turn On / Off the Scale (corresponds to the key I/ in

weighing): Computer

→Scale: S S CR LF (53h 53h

0Dh 0Ah), Scale

→Computer: no response.

ƒ ‘Display the MENU’ (corresponds to the key

MENU in weighing): Computer

→Scale: S F

CR LF (53h 46h 0Dh 0Ah),
Scale

→Computer: no response.


ƒ Setting the threshold 1 (optional):

Computer

→Scale: S L D1...DN CR LF (53h

4Ch D1...DN 0Dh 0Ah) where: D1...DN
Threshold value, up to 8 characters,
Scale

→Computer: no response,

ƒ Example:

To set 1000g in weight B1.5 (d=0.5g) type:
S L 1 0 0 0 . 0 CR LF (53h 4Ch 31h 30h
30h 30h 2Eh 30h 0Dh 0Ah). To set 100kg
in weight B150 (d=50g) type: S L 1 0 0 . 0 0
CR LF (53h 4Ch 31h 30h 30h 2Eh 30h 30h
0Dh 0Ah),

ƒ Setting the threshold 2 (optional):

Computer

→Scale: S H D1...DN CR LF (53h

48h D1...DN 0Dh 0Ah), where: D1...DN
threshold value, up to 8 characters,
Scale

→Computer: no response

Advertising