TP-SCPOE-12XX Series


5.3 Battery Over Charge Protection:

Fuse control, over 10A, the fuse will be burnt.

5.4 Solar Panel Polarity Reverse Protection:

When solar panel polarities be reversed, the charger stop output, it won’t damage
the charger or end device

5.5 Solar Panel Over Charge Protection:

When charge current over 10A, the fuse will be burnt.

5.6 Output Short Circuit Protection:

When the rear output terminal or PoE output be short circuit, protection be active,
the product stop output and auto-recover when the terminal back to normal
connection.

5.7 Battery Output Current Limit:

The fuse will be burnt when battery output current over 10A

5.8 Load Output Voltage Limit:

The output voltage on the rear terminal normally is the same as battery, if the
battery voltage higher than 12.5V, the output voltage on the terminal will be
clamped at 12.5V. The PoE output of TP-SCPOE-1212 with the same limit.

6. GENERAL DESCRIPTION

6.1 Operation Temperature:

-20 - +60 Degree

6.2 Storage Temperature:

-40 - +85 Degree

6.3 Operation Humidity:

5% - 90%

6.4 Cooling:

Free air cooling

6.5 SIZE

150*118*40mm (L*W*H)


7. RJ45 Connected and pin out:

RJ-45 Input (Data & Power)

RJ-45 Output (Data & Power)

Pin

Symbol

Description

Symbol

Description

1

RX+

Data Receive

RX+

Data Receive

2

RX-

Data Receive

RX-

Data Receive

3

TX+

Data Transmit

TX+

Data Transmit

4

(-Vdc)_return +

Feeding power(+)

(-Vdc)_return +

Feeding power(+)

5

(-Vdc)_return +

Feeding power(+)

(-Vdc)_return +

Feeding power(+)

6

TX-

Data Transmit

TX-

Data Transmit

7

-Vdc

Feeding power(-)

-Vdc

Feeding power(-)

8

-Vdc

Feeding power(-)

-Vdc

Feeding power(-)

Advertising