Tech corner, Limited warranty – Tycon Power RPDC12-9-10 User Manual

Page 3

Advertising
background image

3

STEP 7: Tighten the RJ45 Feedthru on the cable. If the cable diam-

eter is too small to make a good seal, wrap a couple turns of electrical

tape around the CAT5 cable at the seal area to increase it’s diameter.

STEP 8: Make sure lid gasket is clean and free from any particles,

then carefully close the cover, making sure that wires are clear of the

seam and hinge area.

STEP 9: Tighten the 4 seal screws evenly to seal the cover. Use a

grease or oil on the 4 cover attached screws to make it easier to re-

move later.

TECH CORNER

Additional Information you may find useful

1. CONTROLLER: The controller turns off power to the load at 11V and

reconnects when the battery reaches 12V. This protects battery from

over-discharge and increases battery life and performance.

2. CAPACITY: The RemotePro RPDC12-9-10 is rated at 2.5W contin-

uous power output with 6 hours of peak sun per day. Reserve battery

capacity at 2.5W load is 36 hours. The RPDC12-9-05 is rated at 1.25W

continuous power.

3. VENTING: The enclosure is vented thru a Goretex Vent in the bot-

tom of the enclosure. Don’t cover this vent.

Limited Warranty

The RemotePro™ products are supplied with a limited 24 month war-

ranty which covers material and workmanship defects. This warranty

does not cover the following:

Parts requiring replacement due to improper installation, misuse,

poor site conditions, faulty power, etc.

Lightning or weather damage.

Physical damage to the external & internal parts.

Products that have been opened, altered, or defaced.

Water damage for units that were not mounted according to user

manual.

Usage other than in accordance with instructions and the normal

intended use.

Advertising