STEP 10: Install the batteries in the

enclosure. If using multiple batteries, con-

nect in parallel for 12V output or connect

in series for 24V output.

A 12V four battery configuration is shown

to the right. If using two batteries it would

be 1/2 what you see here :

A 24V two battery configuration is shown

below:

A 24V four battery configuration is shown

to the right:

If batteries are installed on their side

make sure to apply an in-

sulator to the top of the

battery terminal to prevent

the battery terminals from

shorting to the metal en-

closure in case the battery

shifts inside the enclosure

during an earthquake.

STEP 11: Disconnect the green connector from the front of the

controller. Connect the solar and battery wires to the green connector.

Connect the Battery cables to the Battery. Be sure to observe polarity.

Black wire connects to battery negative terminal and BAT(-) terminal on

the controller. Connect the green connector to the controller. When a

fully charged battery is connected, the Green LOA LED should light on

controller.