Auxiliary output wiring – Tycon Power RPPL2424-18-30 User Manual

Page 3

Advertising
background image

3

connect to the controller solar panel input. Make sure to maintain cor-

rect polarity.

STEP 5:

Install batteries to enclosure using Velcro straps.

STEP 6:

Connect the Battery cables to Controller BAT terminals and

then to the batteries. Be sure to observe polarity. Black wire connects to

battery negative terminal and BAT(-) terminal on the controller. When a

fully charged battery is connected, the Green LOA LED should light on

controller and power should be present on POE output and also green

wire terminal connector.

STEP 7: Make sure lid gasket is clean and free from any particles,

then carefully close the cover, making sure that wires are clear of the

seam and hinge area. The cover snaps into place. There is one center

security bolt that can be used to secure the cover.

NOTE: If you have any unconnected battery connectors on battery

cable after installation, make sure they are wrapped with electrical

tape so that there is no chance of shorting the connector to any

metal. You can also remove the extra cable/connector permanently

by cutting the cable at the existing battery connection.

Auxiliary Output Wiring




Device 1

Device 2

FG = Frame Ground (Do Not Connect

to V-)

GND = V- (There are two V– connec-

tions:1 and 2)

+12V or +24V = V+ (There are two V+

connections: 1 and 2)

+

-