Detects dangerous digital phone

lines and protects your computer

modem from voltage spikes and

surges.

Protect Your Modem!

Recently many businesses and

hotels began using digital phone

systems in place of analog phone

systems. These digital systems

provide high-current phone lines

that can damage most computer

modems. Since both safe analog

lines and dangerous digital lines

use the same type of connectors,

it is impossible to visually

determine if a phone line is safe.

Use Voltage Valet’s Digital Phone

Line Tester before you plug in to

detect

high-current

digital

telephone lines that can damage

your computer modem.

Model PDT
• Detects Dangerous Digital

Phone Lines Or Safe Analog

Lines

• Surge Suppression Circuit

Protects Against Voltage

Spikes And Surges

• Tests 2-Line Phone Systems
• Tests For Polarity
• Uses Standard RJ11 Jack And

Plug NOTE: A Voltage Valet

International Phone Adaptor

may be required when used

outside North America.

©1999 HYBRINETICS, INC.

Voltage Valet Division

Hybrinetics, Inc.

225 Sutton Place

Santa Rosa, CA 95407

D

IGITAL

P

HONE

L

INE

T

ESTER

Digital Phone Line Tester

Model PDT

Instructions

IMPORTANT: Always test the phone line before connecting your computer

modem.

Step 1. Test line 1 by setting the Line Switch to position “1”. Position “1” on

Line Switch tests the inside wire pair. Position “2” on Line Switch tests the

outside wire pair.

Step 2. Connect the RJ11 plug at the LINE end of “Digital Phone Line Tester” to

the RJ11 phone line jack you want to test. NOTE: Outside North America you

may need an International Telephone Outlet Adaptor to convert a foreign

telephone jack to an RJ11 jack. See country list in Voltage Valet’s Foreign

Electricity Guide for proper adaptor.

Step 3. Press the “TEST” button.

RED light indicates a digital line. DO NOT USE LINE.

GREEN light indicates a safe analog line.

YELLOW light indicates a safe analog line with reversed polarity. Phone line

is safe but reversed polarity may slow data transmission rates.

NO LIGHT indicates no signal present on the phone line. Set line switch to

position “2” and repeat steps above.

Step 4. To use the surge suppression circuit, leave the “Digital Phone Line

Tester” plugged into the phone line jack as described in Step 2 and connect the

RJ11 plug from the computer modem to the RJ11 jack at the MODEM end of

“Digital Phone Line Tester.”

One Year Warranty

We guarantee each new Digital Phone Line Tester to be free from defects in material or

workmanship and to perform under normal use and service. This guarantee shall run for a

period of one year from the date of purchase, and obligations under this guarantee are

limited to remedying any defect or replacing any defective part and shall be effective only if

the defective unit is returned to us within 12 months after purchase. Damage due to abuse,

misuse, or overloading is not covered by this guarantee. We shall not be responsible for

any other loss or damage that may arise through the use by a purchaser or others of this

device, and the purchaser assumes such responsibility and will hold Hybrinetics, Inc.

harmless in respect to all such loss or damage.

Important: This is a factory direct warranty. Do not return defectives to your retailer. All

defectives must be returned to the factory accompanied by a sales receipt with the original

date of purchase.

L I N E

T

E

S

T

1

M
O

D

E

M

2

RJ11 PLUG

RJ11 JACK

Red Yellow Green

LINE SWITCH

Voltage Valet Division, Hybrinetics, Inc.

225 Sutton Place, Santa Rosa, CA 95407 Tel: 800 247-6900 Fax: 707 585-7313

e-mail: [email protected] Web site: www.voltagevalet.com

Advertising