BFC36 Balance Flue Heat-Circulating Fireplace

7412647

Finish Glass Doors

The fallaway handles are used to open and close the
front doors. The fallaway handles may be removed
after each use or may be left in place. CAUTION: If the
handles are left in place during operation, they may
become hot. (Fig. 27)
Adjust door alignment by loosening the phillips head
screws which secure the door hinges to the door.
Adjusting one hinge while leaving the other tight will
serve to rotate the inner edge up or down. Adjusting
both hinges at the same time allows the door to adjust
side-to-side.

������
����������������
����

Steel Handle

Fallaway

Handle

Fig. 27 Insert fallaway handle into steel handle.

FP1584

making sure the flat side of the threaded shaft is fac-
ing up and handle stub is pointing down. (Fig. 25)

ST1594

Door Pawl

11/05

FP1594

Fig. 25 Right handle stub in place.

6. Remove small locking nut from left door handle stub

shaft.

7. Insert handle shaft through handle opening in left

door. Secure with small locking nut.

8. Close the left door. To close the right door, turn the

right handle stub to the right and up. Close the door
and turn the handle stub to the left and down to
secure door. (Fig. 26)

������
���������
�����

Left Handle is

Stationary

Turn Counter-

clockwise to

Open

FP1596

Fig. 26 Turn right door handle counterclockwise to open.

KT108b

BFC

Correct door position

8/23/00 djt

Correct

Wrong

Fig. 28 Correct door position.

KT108b

Glass Door Operation

The BFC36 is intended for use only with the doors fully
closed. (Fig. 28)

Glass Door Operation

The BFC36 is intended for use only with the doors fully
closed. (Fig. 28)

Installing Line for Gas Logs

CFM Corporation fireplaces are designed to accept a
1/2” (13mm) gas line for installation of an approved gas
appliance. (CFM Corporation manufactures a wide va-
riety of gas logs for use in CFM Corporation fireplaces.)
Be sure to have the appliance installed in accordance
with building codes.
Gas connection may enter from either left or right side
of the fireplace.
Locate appropriate gas line in the outer casing of fire-
place and remove insulation from gas line tube. (Fig.
29)
From inside the fireplace, locate the knockout on the
firebrick -- be sure you are on the appropriate or “gas
line” side of the fireplace. Using a flat bladed screw-
driver or small chisel and hammer, carefully tap around
the knockout until it loosens and falls out.