OEM Installation of the WFCO WF-8900 Series Power Center

Select a mounting location near the shore power and battery (batteries)
and cut a rough opening 1/8? wider than the box to allow the power
center to slide in easily.

M

During the manufacturing process, be sure that all converter openings
are protected from debris falling into the unit as this could cause the
components to short out. (This is a non-warranty item.)

NOTE: If the reverse battery protection fuses are blown during
installation, be sure that the battery has been connected properly, then
replace the fuses with ATC “Littelfuse ” Type 257 with the same
rating as the original.

This product is not ignition protected and should not be installed in an
LP compartment.

For proper wire sizes and torque requirements, refer to the label on the
back of the door assembly.

ount in an area where the owner is unlikely to store items, as this

could reduce clearance requirements, obstruct ventilation openings
and effect the performance of the converter.
Select a mounting location that is appropriate to prevent excessive
heat, water, moisture, dust and dirt entering the unit installed. As a rule
allow two cubic feet of clear airspace and or any additional venting as
necessary to prevent the unit from overheating. All installation should
be tested for overall performance.

WARNING

!

!

CAUTION

!

!

®

TM

This unit employs components that tend to produce arcs or sparks.

To prevent fire or explosion, do not install in compartments

containing batteries or flammable materials

To prevent fire, do not cover or obstruct ventilation openings.

Do not mount in zero-clearance compartment.

Overheating may result.

For continued protection against risk of fire, or electric shock

replace only with same type and ratings of fuse.

(LP gas).

3

IN

S

T

A

L

L

A

T

IO

N

I

N

S

T

R

U

C

T

IO

N

S

TM

GROUND
WIRE HOLE

Rear view

DC KNOCKOUTS

AC KNOCKOUTS

9/16?

4

?

5

1

1

/1

6

?

1

0

3

/8

?

1

1

?

1

1

1

1

/1

6

?

½?

3/4?

7/8?

12 1/8?

13 3/4?

1/8?

SLIDE RAIL USED FOR

T-30

(OPTIONAL UPGRADE)

UL -Listed Main Circuit Breakers, rated for 120 V, maximum 30 A

Manufacturer
Cutler Hammer
Thomas Betts
ITE/Siemens
Square D

Murray

Model/Cat. No./Type

Type BR and C

Type TB or TBBD

Type QP or QT
Type HOM or HOMT

Type MP-T or MH-T

Acceptable circuit breakers are as follows:

UL-Listed Branch Circuit Breakers, rated for 120 V, maximum 20 A

Manufacturer
Cutler Hammer
Thomas Betts
ITE/Siemens
Square D

Murray

Model/Cat. No./Type

Type BR and C, Type BRD BD and A

Type TB and TBBD

Type QP or QT
Type HOM and HOMT

Type MH-T or MP-T

Acceptable circuit breakers are as follows:

-
type designation, and equal or greater interrupting rating, not to exceed 30 A
- “Short-Circuit-Current” rating for the breaker should be 10,000 A

A replacement or additional circuit breaker shall be of the same manufacturer,

®