WFCO WF-8950 User Manual

Page 2

Advertising
background image

2

IN

S

T

A

L

L

A

T

IO

N

I

N

S

T

R

U

C

T

IO

N

S

UL-Listed Main Circuit Breakers, rated for 30/50 Amp 120V/240 Vac

Breaker Filler Plates:

Manufacturer
Cutler Hammer
ITE/Siemens

Square D

Model/Cat. No./Type

Type BR230, BR250, or C230, or C250
Type QP
Type HOM

Acceptable circuit breakers are as follows:

UL Listed Branch Circuit Breakers, rated for 120/240 Vac, maximum 20 Aac

Manufacturer
Cutler Hammer
ITE/Siemens
Square D

Model/Cat. No./Type

Type Bd2020, A2020

Type QP or QT
Type HOMT

Acceptable circuit breakers are as follows:

Manufacturer
WFCO

Model/Cat. No./Type

FP-01 (brown) or FP-01B (black)

-
type designation, and equal or greater interrupting rating, not to exceed 50 A.
- “Short-Circuit-Current” rating for the breaker should be 10,000 A

A replacement or additional circuit breaker shall be of the same manufacturer,

at 120/240 Volt AC.

General Consumer Information

®

®

TM

This product should be installed by an experienced technician.
CAUTION
and care must be taken when servicing this equipment.
To prevent severe shock or electrocution consult your servicing dealer.
No serviceable parts.

CAUTION

!

!

WARNING

!

!

CAUTION

!

!

®

This unit employs components that tend to produce arcs or sparks.

To prevent fire or explosion, do not install in compartments

containing batteries or flammable materials

To prevent fire, do not cover or obstruct ventilation openings.

Do not mount in zero-clearance compartment.

Overheating may result.

For continued protection against risk of fire, or electric shock

replace only with same type and ratings of fuse.

(LP gas).

Check on a monthly basis the fluid level in any battery connected to RV
charging system.

This product is not ignition protected and should not be installed in an
LP compartment.

CAUTION

!

!

Installation and Servicing of the WFCO WF-8930/50 Series Power Center