Wine Guardian Ducted Wine Cellar Cooling System (D0200) - Manual User Manual

Page 37

Advertising
background image

37

Deg F or Deg C




Setting 1

Press the “Down” arrow to change
temperature from Deg F to Deg C.

Press the “Up” arrow to change temperature
from Deg C to Deg F.

Low temperature
alarm setpoint




Setting 2

Press “Mode” button to advance to Setting 2.

Press the “Up” or “Down” arrow buttons to
adjust to the desired setpoint. Factory default
is 50 Deg. F.

High temperature
alarm setpoint



Setting 3

Press “Mode” button to advance to Setting 3.

Press the “Up” or “Down” arrow buttons to
adjust to the desired setpoint. Factory default
is 65 Deg F.



Low humidity alarm
set point



Setting 4

Press “Mode” button to advance to Setting 4.

Press the “Up” or “Down” arrow buttons to
adjust to the desired setpoint. Factory default
is 5%.




High humidity alarm
setpoint



Setting 5

Press “Mode” button to advance to Setting 5.

Press the up or down arrow buttons to adjust

to the desired setpoint. Factory default is
95%.



Add or remove
humidifier






Setting 6

Press “Mode” button to advance to Setting 6.

Press the “Up” or “Down” arrow buttons to

adjust to the desired setpoint. Factory default
is zero (0).

Zero (0) = No humidifier
One (1) = Integral Wine Guardian mounted
humidifier

Two (2) = Stand-alone remote mounted
humidifier

Fan AUTO or ON



Setting 7

Press “Mode” button to advance to Setting 7.

Press the “Up” or “Down” arrow buttons to
adjust number to the desired set point. Factory
default is zero (0).

Zero (0) = Auto – fan only turns on when
there is a call for cooling or heating

One (1) = Fan On – fan remains on
continuously



Settings – Press and hold the “Mode” button for five seconds to access the following settings.