Maintenance Schedule

Monthly

(or quarterly depending on experience with individual cellar)

 Check and drain trap – clean if needed.

 Check for noise or vibration.

 Check for short-cycling of the unit – a turning on and off of the compressor unit

more than eight times/hour.

Yearly

(in addition to monthly)

 Check evaporator and condensing unit for dirt – use a vacuum with a brush

attachment to clean the coils.

 Clean condensate pan under the evaporator coil by flushing. Be careful to keep the

drain pans clear of any and all debris.

 Inspect cabinet for corrosion or rusting – clean and paint.

 Inspect for dirt buildup on or inside the unit. Clean unit by vacuuming or wiping it

down.

 Check for loose insulation, fasteners, gaskets or connections.

 Check the wiring connections and integrity or cords.

 Examine ducts for any cracks or breach.

 Check fan and solenoid on humidifier.

 Replace humidifier pad (if used).