Output characteristics – Zippy GIH4-6950P User Manual

Page 8

Advertising
background image

INPUT CHARACTERISTICS:

GIH3-6650P

l

VOLTAGE: 90 ~ 264 VAC FULL RANGE

l

FREQUENCY : 47 ~ 63 Hz

l

INPUT CURRENT: 12.0 / 5.0 A FOR 115 / 230 VAC

l

INRUSH CURRENT: 90A / 100A MAX. FOR 115 / 230 VAC PER POWER MODULE

OUTPUT CHARACTERISTICS:

OUTPUT CURRENT

REGULATION

OUTPUT

MIN.[A] MAX.[A] PEAK(A)

LOAD

LINE

5V

3.0

60

± 5%

± 1%

50mV

12V

2

40

± 5%

± 1%

100mV

-5V

0.1

1

± 10%

± 1%

150mV

-12V

0.1

1

± 10%

± 1%

150mV

3.3V

1.0

40

± 5%

± 1%

50mV

+5VSB

0.1

2.5

± 5%

± 1%

50mV

OUTPUT

VOLTAGE

RIPPLE & NOISE

MAX. [P-P]

REMARKS: TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 70 A

TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 630 W

.

TEMPERATURE RANGE : OPERATING 0

0

C --- 40

0

C, STORAGE –20

0

C --- 70

0

C

l

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE

l

DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE

INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE

l

EFFICIENCY: 63% TYPICAL, AT FULL LOAD

l

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

l

OVER LOAD PROTECTION: 110 ~ 160% MAX.
OVER VOLTAGE PROTECTION:
+5V

à 5.7V ~ 6.7V, 3.3V à 3.7 ~ 4.7V, 12V à 13.0 ~ 15.0V

. SHORT CIRCUIT : 5V,12V, 3.3V, AUTO-RECOVERED : 5VSB, -5V, -12V

l

EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B

l

SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950

l

REMOTE ON / OFF CONTROL

l

FAULTY ALERT METHODS : LED, BUZZER, TTL SIGNAL

l

2 + 1, HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION

l

N + 1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL

l

REMOTE SENSING DESIGN

l

ISOLATION: BUILT-IN IN THE POWER MODULE

l

MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )

l

DIMENSION: 41(H) X 290(W) X 330 (D) mm,

l

COOLING : THREE 40 mm DC FANS ( ONE IN EACH MODULE )

Advertising
This manual is related to the following products: