Total output power not exceed 500w, Output characteristics – Zippy R2W-5600P3V User Manual

Page 6

Advertising
background image

INPUT CHARACTERISTICS:

R2W-6500P

l

VOLTAGE: 100 ~ 240 VAC (WITH 5% TOLERANCE)

l

FREQUENCY : 47 ~ 63 Hz

l

INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC

l

INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE

OUTPUT CHARACTERISTICS:

OUTPUT CURRENT

REGULATION

OUTPUT

MIN.[A] MAX.[A] PEAK(A)

LOAD

LINE

5V

3.5

30

± 5%

± 1%

70mV

12V

2

32

± 5%

± 1%

120mV

-5V

0.05

0.7

+5/-10%

± 1%

120mV

-12V

0.05

0.7

+5/-10%

± 1%

120mV

3.3V

1.0

24

± 5%

± 1%

70mV

+5VSB

0.1

2.0

+ 6/-5%

± 1%

70mV

OUTPUT

VOLTAGE

RIPPLE & NOISE

MAX. [P-P]

REMARKS: TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 43 A;

total

output power not exceed 500w

.

TEMPERATURE RANGE : OPERATING 0

0

C --- 40

0

C, STORAGE –20

0

C --- 70

0

C

l

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE

l

DIELECTRIC WITHSTAND: INPUT / OUTPUT 1800 VAC FOR 1 MINUTE

INPUT TO FRAME GROUND 1800 VAC FOR 1 MINUTE

l

EFFICIENCY: 67% TYPICAL, AT FULL LOAD 115V

l

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

l

OVER LOAD PROTECTION: 110 ~ 170% MAX.
OVER VOLTAGE PROTECTION:
+5V

à 5.7V ~ 6.6V, 3.3V à 3.9 ~ 4.4V, 12V à 13.6 ~ 15.0V

. OVER CURRENT PROTECTION

EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B

l

SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950

l

REMOTE ON / OFF CONTROL

l

FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL

l

HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION

l

REMOTE SENSING DESIGN

l

ISOLATION: BUILT-IN IN THE POWER MODULE

l

MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )

l

DIMENSION: 84(H) X 101(W) X 300 (D) mm

l

COOLING : TWO 38x38x28 mm DC FANS (MODULE)

l

AC INLET IN EACH MODULE

Advertising