Trouble shooting – Zippy ARD-6400F User Manual

Page 35

Advertising
background image

2 WHITE

SCL

1.9. TROUBLE SHOOTING

If you have followed these directions correctly, there should be no problem. Same common

symptoms are: the system doesn’t work, buzzer sound, work for a very short period, etc.,

please try the following steps to verify and correct it:

1. Check all the connections (correct pinouts, loose connections, wrong direction, etc.)

2. Check for short-circuits or defective peripherals by unhooking each peripheral once at a

time. When the systems functions again, you have solved the problem.

3. Once you hear the buzzer sound or see the LED with RED light, please be aware of:

a. IF the load is under the minimum / over the maximum load of each channel (Please

refer the sec. 1.5 Specification)?

b. IF AC/DC input voltage been set correct?

c. IF each power cord been well plugged into the inlet?

Suppose the above condition been happened, please unplug the power cords, await for 2 – 3

minutes for releasing the protection state, then test it again.

d. IF buzzer still sound or the LED shows power module is defective, please locating

which power module is defective, perform hot-swap procedure (please refer to the

HOT-SWAP PROCEDURES), send the defective power module to your vendor for

RMA operation.

e. IF you can not fix the problem, please contact with your vendor for supporting.

The description stated herein is subject to

change without prior notice.

All brand names and trademarks are the

property of their respective owners.

Advertising
This manual is related to the following products: